Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 6.15
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Check the
LED
1
(
green
) of
the Display Board, is correctly lit on.
(2)
Place the tester probes across pins
3
and
1
of
CN4
connectors on the Brake board. The
measured value should be approximately 220Vac or 110Vac depending on the mains voltage.
(3)
Slightly lift up the fast on the machine power entry module. Place the tester probes across the
live and neutral pins on the same connector. The measured value should be approximately
220Vac or 110Vac depending on the mains voltage.
(4)
Using a tester, check that all the output voltages on connector
CN1
of the Brake board. The
measured value should be:
•
+12Vdc between pins
6
-
2
;
•
+5Vdc between pins
7
-
3
.
Place the tester probes across pins
1
and
2
of
CN15
of Display Board. The measured value
should be +12Vdc..
If you replace Display Board and/or Brake Board, check that its SW version is updated,
otherwise install the last version.
The TV and RADIO channels are only stored in a file in the FLASH memory. Then the
channels will be re-storing the replacement of the CPU Board.
Содержание WAVE EXCITE+
Страница 1: ...W WA AV VE E E X C I T E REV 4 1...
Страница 2: ......
Страница 4: ......
Страница 10: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina vi Page intentionally left blank...
Страница 32: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 2 20 Page intentionally left blank...
Страница 50: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 3 18 Page intentionally left blank...
Страница 184: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 9 26 Page intentionally left blank...
Страница 186: ...Cardio WAVE EXCITE Service maintenance manual rev 4 1 Pagina 10 2 Page intentionally left blank...
Страница 197: ......