Cardio WAVE : Service & maintenance manual - rev. 4.1
Pagina 7.29
7.8.
DISASSEMBLING THE UPPER COLUMN
Figure 7.8-1
Carry out the operations described in
paragraphs: 7.7. “Disassembling the guards”,
only the anterior guard.
1.
Back off the screws
(a)
using a 17mm
wrench.
Figure 7.8-2
2.
Back off the screws
(b)
using a 17mm
wrench.
3.
Remove the upper part of the column pulling
it out from the top. Pay attention to unplug
the junction connectors of the cables which
goes from the display to the lower electronic.
Figure 7.8-3
To reassemble the upper column, carry out the
above steps in reverse order.
CAUTION: During reassembly, lock
down the screws (a) and (b) using a
torque wrench setting of 40Nm.
Pay attention the cables are properly
connected inside the frame, as shown in
figure.