Connection
It is mandatory to use mains switch and fuses for connecting the device to mains power (L and N) and
the total power consumption of all modules should be taken into account!
The whole product including all of inside electric units should be earthed (connected to PE)!
Inputs
Pt1000
t1
Temperature sensor flue gases
NTC 10K
t2
Temperature sensor boiler
NTC 10K / On - Off
t3
Temperature sensor room temperature / thermostat
NTC 10K
t4
Temperature sensor DHW
Light sensitive
i1
Light sensor flame intensity
Active level
GND
i2
Hall sensor for fan revolutions counting
i3
Capacitive / inductive sensor for pellet level / position of cleaner mechanism
Opto-insulated
input 230V AC
e1
Error Bunker fire (Overheat Bunker)
e2
Error Fume pressure / Door
230V 50Hz
MAINS
Mains power, internally fused 3.15А
Outputs
Relay
O3
Lighter
Triac
O1
Feeder main(fuel feeding mechanism)
O2
Feeder internal
O4
Fumes fan
O5
Boiler pump (water pump / fan)
O6
DHW pump
O7
Clean / Chimney fan