Issue/Rev. 0.1 (2/20) ║ MN06201 • Page 29
AccuLoad IV Installation and Maintenance Manual
General Wiring Notes
7 – General Wiring Notes
7.1.
AC Input Power
There are two AC power inputs to the AccuLoad A4M board. The first is the instrument
power which powers the AccuLoad electronics and is connected to the A4M at TB1 (see
figure 9). The instrument power should be “clean” and must meet the requirements
listed in the specification
. The second AC power input to the AccuLoad is used to
drive external AC equipment such as solenoids and therefore will be “noisier” so it should
be supplied to the AccuLoad by a separate circuit from the power panel.
Figure 12.
AC power inputs to AccuLoad A4M board
Figure 13.
Example of the AC wiring of a typical AccuLoad
Power
Distribution
Panel
Separate
Curcuits
Field I/O
Power
AccuLoad
Instrument
Power TB1
Terminal Board Key
Содержание ALIV-QT-XP