Page 28 • MN06201 ║ Issue/Rev. 0.1 (2/20)
AccuLoad IV Installation and Maintenance Manual
Electronic Module Layouts
6.3.
A4I Board
The replaceable parts on the A4I board are the power fuse and AC Digital output relays.
Refer to parts list for details.
Figure 11.
A4I Board Layout
Table 13.
A4I switch settings
A4I Switch Settings
S1-1
Factory Use - Always OFF
S1-2
Module Address - Off =100, On = 200
S1-3
Serial Baud Rate - Off = 9600, On = 38400
S1-4
Serial Mode - Off = RS232, On = RS485
S1-5
Serial Termination resistors - Off = Disable, On = Enable
S1-6
Reserved
S1-7
Model SA Board Set Selector - for SA model see section 10. Off for all other models
S1-8
Model SA Board Set Selector - for SA model see section 10. Off for all other models
U22
TB
5
TB
4
U4
S1
P1
U5
P8
S2
U27
SSR8
SSR18
SSR19
SSR20
SSR17
SSR16
SSR15
SSR14
SSR13
SSR12
SSR11
SSR10
SSR9
SSR7
SSR6
SSR5
SSR4
SSR3
SSR2
SSR1
TB
3
TB
2
TB
1
C5
C14
F1
D3
TB
7
TB
6
TB
8
TB
9
CN1
LMOD1
CN2
U9
U11
U10
CN3
ETH2
ETH1
Ethernet Connections
See table 13
for Switch
Settings
Power
Fuse
AC Digital
Output Relays
24V
12V
5V
Содержание ALIV-QT-XP
Страница 8: ...Page 8 MN06201 Issue Rev 0 1 2 20 Page intentionally left blank ...
Страница 12: ...Page 12 MN06201 Issue Rev 0 1 2 20 Page intentionally left blank ...
Страница 16: ...Page 16 MN06201 Issue Rev 0 1 2 20 Page intentionally left blank ...
Страница 62: ...Page 62 MN06201 Issue Rev 0 1 2 20 Page intentionally left blank ...
Страница 66: ...Page 66 MN06201 Issue Rev 0 1 2 20 Page intentionally left blank ...