02-OM-06-02
4
30.07.2014
36
74
Revision no.:
Revision date:
7
20.07.2016
5.
Fill in the new gearbox oil until the oil level reaches the top
border of the oil level inspection glass (marking line in
Fig. 6.24). Air bubbles must not be visible.
6.
Remount the oil filler screw with a new sealing ring and
tighten it to the specified tightening torque.
Tightening Torque:
35 Nm
7.
Preset the proportional pressure reducing valve. Refer to
Chapter 72-10.05 of RM-02-02.
Fig. 6.25
Gearbox oil filler screw and inspection glass
a Oil filler screw
b Oil level inspection glass
a
b
Note:
Before refilling, shake the gearbox oil bottle, in order to mix the
gearbox oil and the additives.