background image

8

EG

REMOTE CONTROL UNIT

“NIGHT” BUTTON

For details, see "NIGHT MODE".
When you press this button in the COOL,
HEAT

or DRY

mode, the mark

appears  on the display and the
microcomputer in the remote control unit
will adjust the set temperature to save
energy.

TRANSMITTER

When you press the buttons of the remote
control unit, the           mark
appears on the display to transmit the
setting changes to the receiver in the air
conditioner.

TEMPERATURE SETTING BUTTONS

TEMP -  (cooler)
Press this button to decrease the set
temperature.

TEMP + (warmer)
Press this button to increase the set
temperature.

SENSOR

A temperature sensor inside the remote
control unit detects the room temperature.

“SEL TYPE” BUTTON
Press this button in order to:
• set the clock
• set the ON/OFF timer
For details refer to paragraphs “SETTING
THE HOUR” and “SETTING THE TIMER”.

TEMPERATURE SENSOR SELECTOR
Press the I FEEL button to modify the
active setting for room temperature
detection (from remote controller to air
conditioner and viceversa)

“FAN “ BUTTON

Fan speed is automatically
selected by the microcomputer.

High speed.

Medium speed.

Low speed.

TIMER AND PRESENT TIME SETTING
BUTTONS

With these buttons is possible to set the
clock and the timer. For details refer to
paragraphs “ SETTING THE HOUR” and
“SETTING THE TIMER2.

“TIMER SEL” BUTTON
Press this button to select the type of
timer to activate. For details refer to
paragraph “SETTING THE TIMER”.

DISPLAY
Information is displayed when the remote controller is switched on. If switched off, only the operating mode, the room
temperature and the clock are shown

Operation mode

Fan speed

High speed

Automatic

Medium speed

Low speed

Displayed when
transmitting data 

Set point
temperature

I FEEL mode is active 
(remote controller
sensor active)

Timer modes

Automatic

Cooling

Heating

Dehumidification 

Fan

MODE SELECTOR BUTTON
Press this button to modify the air conditioner mode.

(automatic)  

(

When this setting is selected, the air conditioner
calculates the difference between the thermostat setting
and the room temperature and automatically switches to
the "cool" or "heat" mode.

(heating)  

(

The air conditioner makes the room warmer.

(dry)   

The air conditioner reduces the humidity in the room.

(cooling)

The air conditioner makes the room cooler.

(fan)

The air conditioner works only as a circulation fan.

(

Available only for models

COOL / DRY / HEAT /FAN

Clock

Room
temperature

Night
mode

Oscillation
Flap

PUSH-BUTTON FLAP
To press this push-button in order to
select the wished function.

: To press this push-button in

order to select the wished function.

: The baffle plate oscillates

automatically

INACTIVE BUTTONS

ON/OFF BUTTON
This button turns the air conditioner ON
and OFF.

Содержание REVE 237R

Страница 1: ...CCIONES DE USO INSTALLATION INSTRUCTION ISTRUZIONI D INSTALLAZIONE NOTICE D INSTALLATION INSTALLATIONSANLEITUNGEN INSTRUCCIONES DE INSTALACION REVE 247C 37 4252 028 2 11 2009 Air conditioner Climatizz...

Страница 2: ...TING OUTDOOR TEMPERATURE 24 C D B 18 C W B ROOM TEMPERATURE 27 C D B OUTDOOR TEMPERATURE 8 C D B 9 C W B ROOM TEMPERATURE OUTDOOR TEMPERATURE 43 C B S ROOM TEMPERATURE 32 C B S 80 R H OUTDOOR TEMPERAT...

Страница 3: ...receive the remote control command 4 Operation lamp This lamp lights up during operation It blinks once to announce that the remote control signal has been received and stored It blinks continuously d...

Страница 4: ...lection of the installation site according to the above mentioned points be sure not to make holes in areas where electrical wiring or conduits are located damaging them Make sure that there are no ob...

Страница 5: ...ok of the spring insert them inside the tube and open them toward the outside b Choose the proper hook of the tension bar in order to lengthen the spring of 15 20 mm and hook it to the internal grille...

Страница 6: ...scale diagram The quantity and the type of rawl plugs not supplied depends on the consistence of the wall do not let any space between the panel and the wall Hang up the unit at the panel inserting t...

Страница 7: ...is provided with an earth connection in compliance with local codes Never use the power plug as a mean to start or stop the air conditioner always use the ON OFF button of the remote control unit or t...

Страница 8: ...TRANSMITTER HEAD REMOTE CONTROL UNIT UNIT RECEIVER The remote control unit sends the temperature signal at any key pressing and automatically every five minutes If due to some troubles the signal fro...

Страница 9: ...phs SETTING THE HOUR and SETTING THE TIMER2 TIMER SEL BUTTON Press this button to select the type of timer to activate For details refer to paragraph SETTING THE TIMER DISPLAY Information is displayed...

Страница 10: ...efrosting is completed Heating operation restarts after several minutes This interval will vary slightly depending on the room and outdoor temperature HEATING PERFORMANCE A heat pump conditioner heats...

Страница 11: ...follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When the room temperature reaches the new set value the thermostat wi...

Страница 12: ...art the air conditioner 4 Press the TIMER SEL button two times to activate the OFF timer C HOW TO SET A PROGRAM FOR DAILY ON OFF OPERATION OR VICEVERSA 1 Set the timer ON OFF as shown in A and B 2 Pre...

Страница 13: ...will stop When the power is resumed the unit will restart automatically after 3 minutes NOTE Operation button Heat pump models Cooling only models TROUBLESHOOTING Trouble the air conditioner does not...

Страница 14: ...raph HOW TO DISCHARGE THE CONDENSATE WATER EG Always switch off the air conditioner before unplugging it from the power socket Always unplug the air conditioner before discharging the condensate water...

Страница 15: ...ater then rinse in clean cold water and dry it before reinstallation 2 Cleaning of Casing and Grilles To clean the air conditioner wipe it with a clean soft cloth lightly moisted In case it is stained...

Страница 16: ...ATE RELAY REL STATO SOLIDO RELAIS A SEMI CONDUCTEUR FESTK RPERRELAIS REL DEL ESTADO S LIDO REL DO ESTADO S LIDO RA STARTING RELAY REL DI AVVIAMENTO RELAIS DE DEMARRAGE STARTRELAIS REL DE ARRANQUE REL...

Отзывы: