background image

2

EG

PRODUCT IDENTIFICATION

1.

Wireless remote control unit

2.

Signaling lamps

3.

Supply air deflector

4.

Lateral air intake grilles 

5.

Front air intake grille

6.

Air filter

7.

Electric cable with plug

8.

Air inlet hole

9.

Air outlet fan

10. Suspension panel  

11. Service tube for condensate

discharge 

12. Tube for condensate discharge 

(heat pump models) 

SIGNALING LAMPS

1. Receiver : receives signals transmitted from the remote

control.

2. Timer lamp: This lamp lights up when the system is

being controlled by the timer.

3. Standby lamp: This lamp lights up when the air

conditioner is connected to the power and ready to
receive the remote control command.

4. Operation lamp: This lamp lights up during operation.

It blinks once to announce that the remote control signal
has been received and stored. It blinks continuously
during the protection modes (defrosting, etc.).

5. Operation button (without remote control): Push the

button to change from one operation mode to the other
as shown here following.

The OFF position does not disconnect the power. Use
the main power switch to turn off power completely.

WARNING

Heat pump models

Cooling only models

1

2

3

4

5

6

7

8

9

10

11

11

12

Heat pump models

Cooling only models

NOTE

The blinking of OPERATION, TIMER and STANDBY
lamps, indicates that the operating mode selected
(          ) is not compatible with the unit. If this happen
the air conditioner does not operate until the correct
mode is selected.

Содержание REVE 237R

Страница 1: ...CCIONES DE USO INSTALLATION INSTRUCTION ISTRUZIONI D INSTALLAZIONE NOTICE D INSTALLATION INSTALLATIONSANLEITUNGEN INSTRUCCIONES DE INSTALACION REVE 247C 37 4252 028 2 11 2009 Air conditioner Climatizz...

Страница 2: ...TING OUTDOOR TEMPERATURE 24 C D B 18 C W B ROOM TEMPERATURE 27 C D B OUTDOOR TEMPERATURE 8 C D B 9 C W B ROOM TEMPERATURE OUTDOOR TEMPERATURE 43 C B S ROOM TEMPERATURE 32 C B S 80 R H OUTDOOR TEMPERAT...

Страница 3: ...receive the remote control command 4 Operation lamp This lamp lights up during operation It blinks once to announce that the remote control signal has been received and stored It blinks continuously d...

Страница 4: ...lection of the installation site according to the above mentioned points be sure not to make holes in areas where electrical wiring or conduits are located damaging them Make sure that there are no ob...

Страница 5: ...ok of the spring insert them inside the tube and open them toward the outside b Choose the proper hook of the tension bar in order to lengthen the spring of 15 20 mm and hook it to the internal grille...

Страница 6: ...scale diagram The quantity and the type of rawl plugs not supplied depends on the consistence of the wall do not let any space between the panel and the wall Hang up the unit at the panel inserting t...

Страница 7: ...is provided with an earth connection in compliance with local codes Never use the power plug as a mean to start or stop the air conditioner always use the ON OFF button of the remote control unit or t...

Страница 8: ...TRANSMITTER HEAD REMOTE CONTROL UNIT UNIT RECEIVER The remote control unit sends the temperature signal at any key pressing and automatically every five minutes If due to some troubles the signal fro...

Страница 9: ...phs SETTING THE HOUR and SETTING THE TIMER2 TIMER SEL BUTTON Press this button to select the type of timer to activate For details refer to paragraph SETTING THE TIMER DISPLAY Information is displayed...

Страница 10: ...efrosting is completed Heating operation restarts after several minutes This interval will vary slightly depending on the room and outdoor temperature HEATING PERFORMANCE A heat pump conditioner heats...

Страница 11: ...follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When the room temperature reaches the new set value the thermostat wi...

Страница 12: ...art the air conditioner 4 Press the TIMER SEL button two times to activate the OFF timer C HOW TO SET A PROGRAM FOR DAILY ON OFF OPERATION OR VICEVERSA 1 Set the timer ON OFF as shown in A and B 2 Pre...

Страница 13: ...will stop When the power is resumed the unit will restart automatically after 3 minutes NOTE Operation button Heat pump models Cooling only models TROUBLESHOOTING Trouble the air conditioner does not...

Страница 14: ...raph HOW TO DISCHARGE THE CONDENSATE WATER EG Always switch off the air conditioner before unplugging it from the power socket Always unplug the air conditioner before discharging the condensate water...

Страница 15: ...ater then rinse in clean cold water and dry it before reinstallation 2 Cleaning of Casing and Grilles To clean the air conditioner wipe it with a clean soft cloth lightly moisted In case it is stained...

Страница 16: ...ATE RELAY REL STATO SOLIDO RELAIS A SEMI CONDUCTEUR FESTK RPERRELAIS REL DEL ESTADO S LIDO REL DO ESTADO S LIDO RA STARTING RELAY REL DI AVVIAMENTO RELAIS DE DEMARRAGE STARTRELAIS REL DE ARRANQUE REL...

Отзывы: