2
EG
PRODUCT IDENTIFICATION
1.
Wireless remote control unit
2.
Signaling lamps
3.
Supply air deflector
4.
Lateral air intake grilles
5.
Front air intake grille
6.
Air filter
7.
Electric cable with plug
8.
Air inlet hole
9.
Air outlet fan
10. Suspension panel
11. Service tube for condensate
discharge
12. Tube for condensate discharge
(heat pump models)
SIGNALING LAMPS
1. Receiver : receives signals transmitted from the remote
control.
2. Timer lamp: This lamp lights up when the system is
being controlled by the timer.
3. Standby lamp: This lamp lights up when the air
conditioner is connected to the power and ready to
receive the remote control command.
4. Operation lamp: This lamp lights up during operation.
It blinks once to announce that the remote control signal
has been received and stored. It blinks continuously
during the protection modes (defrosting, etc.).
5. Operation button (without remote control): Push the
button to change from one operation mode to the other
as shown here following.
The OFF position does not disconnect the power. Use
the main power switch to turn off power completely.
WARNING
Heat pump models
Cooling only models
1
2
3
4
5
6
7
8
9
10
11
11
12
Heat pump models
Cooling only models
NOTE
The blinking of OPERATION, TIMER and STANDBY
lamps, indicates that the operating mode selected
( ) is not compatible with the unit. If this happen
the air conditioner does not operate until the correct
mode is selected.