BEFORE USING THE APPLIANCE

Check that the power supply at the location where the air conditioner is going to be used is 220-240V ~ 50Hz .

Make sure that the electrical installation is suitable to supply continuously  current necessary for the air conditioner in
addition to that already used by other electric appliances (white goods, lighting). See the max electric input indicated
on the name plate positioned on the air conditioner.

The installation of a double-pole switch, protected by 10 A fuses of the delayed type, upstream the electricity wall socket,
is recommended.

The unit has to be connected according to the local electrical rules.

Make sure that circuit breakers, fuses, etc, are of sufficient capacity to handle a start-up current of 20 A (generally less
then 1 second).

Do not install the air conditioner where it could be wetted by drops of water (i.e. in laundries).

Before connecting the air conditioner to a power socket, make sure that the socket is provided with an earth connection
in compliance with local codes.

Never use the power plug as a mean to start or stop the air conditioner: always use the ON/OFF button of the remote
control unit or the operation button on the unit.

WARNING! Do not stick anything into the air outlet of the air conditioner. This is very dangerous because the fan is rotating
at high speed.

WARNING!
The air conditioner is provided with a time-guard system, which does not allow re-starting of compressor until after 3
minutes from a previous stop. 

Make sure that there are no obstacles around the unit affecting the free circulation of air. Do not block the air intakes
and outlet of the unit with curtains or other. Never put objects on the top of the unit.

When you switch on the air conditioner for the first time, it reaches the maximum efficiency after at least one hour of
operation.

The manufacturer assumes no responsibilities if the safety regulations or local codes are not observed.

Always unplug the unit from the power socket before moving or cleaning it and, in case you should remove it, discharge
the eventual condensate water inside the bottom plate.

WARNING

EG

Содержание REVE 237R

Страница 1: ...CCIONES DE USO INSTALLATION INSTRUCTION ISTRUZIONI D INSTALLAZIONE NOTICE D INSTALLATION INSTALLATIONSANLEITUNGEN INSTRUCCIONES DE INSTALACION REVE 247C 37 4252 028 2 11 2009 Air conditioner Climatizz...

Страница 2: ...TING OUTDOOR TEMPERATURE 24 C D B 18 C W B ROOM TEMPERATURE 27 C D B OUTDOOR TEMPERATURE 8 C D B 9 C W B ROOM TEMPERATURE OUTDOOR TEMPERATURE 43 C B S ROOM TEMPERATURE 32 C B S 80 R H OUTDOOR TEMPERAT...

Страница 3: ...receive the remote control command 4 Operation lamp This lamp lights up during operation It blinks once to announce that the remote control signal has been received and stored It blinks continuously d...

Страница 4: ...lection of the installation site according to the above mentioned points be sure not to make holes in areas where electrical wiring or conduits are located damaging them Make sure that there are no ob...

Страница 5: ...ok of the spring insert them inside the tube and open them toward the outside b Choose the proper hook of the tension bar in order to lengthen the spring of 15 20 mm and hook it to the internal grille...

Страница 6: ...scale diagram The quantity and the type of rawl plugs not supplied depends on the consistence of the wall do not let any space between the panel and the wall Hang up the unit at the panel inserting t...

Страница 7: ...is provided with an earth connection in compliance with local codes Never use the power plug as a mean to start or stop the air conditioner always use the ON OFF button of the remote control unit or t...

Страница 8: ...TRANSMITTER HEAD REMOTE CONTROL UNIT UNIT RECEIVER The remote control unit sends the temperature signal at any key pressing and automatically every five minutes If due to some troubles the signal fro...

Страница 9: ...phs SETTING THE HOUR and SETTING THE TIMER2 TIMER SEL BUTTON Press this button to select the type of timer to activate For details refer to paragraph SETTING THE TIMER DISPLAY Information is displayed...

Страница 10: ...efrosting is completed Heating operation restarts after several minutes This interval will vary slightly depending on the room and outdoor temperature HEATING PERFORMANCE A heat pump conditioner heats...

Страница 11: ...follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When the room temperature reaches the new set value the thermostat wi...

Страница 12: ...art the air conditioner 4 Press the TIMER SEL button two times to activate the OFF timer C HOW TO SET A PROGRAM FOR DAILY ON OFF OPERATION OR VICEVERSA 1 Set the timer ON OFF as shown in A and B 2 Pre...

Страница 13: ...will stop When the power is resumed the unit will restart automatically after 3 minutes NOTE Operation button Heat pump models Cooling only models TROUBLESHOOTING Trouble the air conditioner does not...

Страница 14: ...raph HOW TO DISCHARGE THE CONDENSATE WATER EG Always switch off the air conditioner before unplugging it from the power socket Always unplug the air conditioner before discharging the condensate water...

Страница 15: ...ater then rinse in clean cold water and dry it before reinstallation 2 Cleaning of Casing and Grilles To clean the air conditioner wipe it with a clean soft cloth lightly moisted In case it is stained...

Страница 16: ...ATE RELAY REL STATO SOLIDO RELAIS A SEMI CONDUCTEUR FESTK RPERRELAIS REL DEL ESTADO S LIDO REL DO ESTADO S LIDO RA STARTING RELAY REL DI AVVIAMENTO RELAIS DE DEMARRAGE STARTRELAIS REL DE ARRANQUE REL...

Отзывы: