background image

EG

11

ADJUSTING THE AIR FLOW DIRECTION

Set vertical vanes to the front position during COOLING/DRY
operation if humidity is high. 
If the vertical vanes are set  to the left-most or right-most
position, condensation will form around the air outlet and
drip off.

CAUTION

TIMER SETTING PROCEDURE.

Press four times the TIMER SEL
button.The 1 HOUR TIMER mark will
appear on the display.

CANCELLATION PROCEDURE

• Press the ON/OFF button to turn the air

conditioner off.

• Wait for the indoor unit to stop operating.
• Press the ON/OFF button again to turn

the air conditioner on.

SETTING THE 1 HOUR TIMER

This function causes the unit to operate for one hour at the set
conditions, regardless of whether the unit is on or off.

A) HOW TO SET THE ON TIME

1. Press the SEL TYPE button once.

The ON and time indications flash.

2. Press the SET H button until the designed

hour is displayed.
Press the SET M button until the designed
minutes are displayed.  The display will
change automatically back to show the
present time after 10 sec.

3. Press the ON/OFF button to start the air

conditioner.

4. Press the TIMER SEL button to activate

the ON timer.

B) HOW TO SET THE OFF TIME

1. Press the SEL TYPE button twice.

The OFF and time indications flash.

2. Press the SET H button until the designed

hour is displayed.
Press the SET M button until the designed
minutes are displayed. The display will
change automatically back to show the
present time after 10 sec.

3. Press the ON/OFF button to start the air

conditioner.

4. Press the TIMER SEL button two times to

activate the OFF timer.

C) HOW TO SET A PROGRAM FOR DAILY

ON/OFF OPERATION (OR VICEVERSA)

1. Set the timer ON/OFF as shown in A) and

B).

2. Press the ON/OFF button to start the air

conditioner.

3. Press three times the TIMER SELECT

button to activate the DAILY timer.

SETTING THE TIMER

After timer setting, press PROGRAM button in order to check the
ON/OFF setting time.

NOTE

2

1

4

3

HORIZONTAL (manual)

The horizontal air flow can be adjusted by moving the vertical
vanes to the left or right, as indicated in the following figures.

VERTICAL (with remote control unit)

Make sure that the remote control unit has been turned on. Press
the FLAP button to select the sweep function or to choose one of
the six positions of the flap.

CAUTION

Do not move the flap with your hands when the air conditioner
is running.

Vertical vane

Sweep function
The flap starts moving up and down to deliver air over the
sweep range.

NOTES

• The flap automatically closes when the unit is off.
• During the heating operation, the fan speed will be very low and

the flap will be in the horizontal position (position 

d

) until the air

being blown out of the unit begins to warm. Once the air warms
up, the flap position and fan speed change to the settings
specified with the remote control.

• Use the FLAP button on the remote control to adjust the

position of the flap. If you move the flap by hand, the factual
flap position and the flap position on the remote control
may no longer match. If this should happen, shut off the
unit, wait for the flap to close, and then turn on the unit
again; the flap position will now be normal again.

CAUTION

Содержание REVE 237R

Страница 1: ...CCIONES DE USO INSTALLATION INSTRUCTION ISTRUZIONI D INSTALLAZIONE NOTICE D INSTALLATION INSTALLATIONSANLEITUNGEN INSTRUCCIONES DE INSTALACION REVE 247C 37 4252 028 2 11 2009 Air conditioner Climatizz...

Страница 2: ...TING OUTDOOR TEMPERATURE 24 C D B 18 C W B ROOM TEMPERATURE 27 C D B OUTDOOR TEMPERATURE 8 C D B 9 C W B ROOM TEMPERATURE OUTDOOR TEMPERATURE 43 C B S ROOM TEMPERATURE 32 C B S 80 R H OUTDOOR TEMPERAT...

Страница 3: ...receive the remote control command 4 Operation lamp This lamp lights up during operation It blinks once to announce that the remote control signal has been received and stored It blinks continuously d...

Страница 4: ...lection of the installation site according to the above mentioned points be sure not to make holes in areas where electrical wiring or conduits are located damaging them Make sure that there are no ob...

Страница 5: ...ok of the spring insert them inside the tube and open them toward the outside b Choose the proper hook of the tension bar in order to lengthen the spring of 15 20 mm and hook it to the internal grille...

Страница 6: ...scale diagram The quantity and the type of rawl plugs not supplied depends on the consistence of the wall do not let any space between the panel and the wall Hang up the unit at the panel inserting t...

Страница 7: ...is provided with an earth connection in compliance with local codes Never use the power plug as a mean to start or stop the air conditioner always use the ON OFF button of the remote control unit or t...

Страница 8: ...TRANSMITTER HEAD REMOTE CONTROL UNIT UNIT RECEIVER The remote control unit sends the temperature signal at any key pressing and automatically every five minutes If due to some troubles the signal fro...

Страница 9: ...phs SETTING THE HOUR and SETTING THE TIMER2 TIMER SEL BUTTON Press this button to select the type of timer to activate For details refer to paragraph SETTING THE TIMER DISPLAY Information is displayed...

Страница 10: ...efrosting is completed Heating operation restarts after several minutes This interval will vary slightly depending on the room and outdoor temperature HEATING PERFORMANCE A heat pump conditioner heats...

Страница 11: ...follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When the room temperature reaches the new set value the thermostat wi...

Страница 12: ...art the air conditioner 4 Press the TIMER SEL button two times to activate the OFF timer C HOW TO SET A PROGRAM FOR DAILY ON OFF OPERATION OR VICEVERSA 1 Set the timer ON OFF as shown in A and B 2 Pre...

Страница 13: ...will stop When the power is resumed the unit will restart automatically after 3 minutes NOTE Operation button Heat pump models Cooling only models TROUBLESHOOTING Trouble the air conditioner does not...

Страница 14: ...raph HOW TO DISCHARGE THE CONDENSATE WATER EG Always switch off the air conditioner before unplugging it from the power socket Always unplug the air conditioner before discharging the condensate water...

Страница 15: ...ater then rinse in clean cold water and dry it before reinstallation 2 Cleaning of Casing and Grilles To clean the air conditioner wipe it with a clean soft cloth lightly moisted In case it is stained...

Страница 16: ...ATE RELAY REL STATO SOLIDO RELAIS A SEMI CONDUCTEUR FESTK RPERRELAIS REL DEL ESTADO S LIDO REL DO ESTADO S LIDO RA STARTING RELAY REL DI AVVIAMENTO RELAIS DE DEMARRAGE STARTRELAIS REL DE ARRANQUE REL...

Отзывы: