10

DMX-512 Control

 

Fixtures require a "Start Address" from 1 to 512, setting the first DMX channel containing data 
for the fixture (see DMX Background).  Before addressing fixtures, consult the manual of the 
system’s DMX controller to select a desirable addressing scheme.  Valid Start Addresses range 
from 1 to 512.  Fixtures requiring more than one channel for control will read subsequent 
channels up to the total number of channels required.  Since this fixture requires a maximum of 
3 channels of DMX, if set to a Start Address of 4 it would use data from channels: 4, 5 and 6.   
Choose a Start Address so the channels used do not overlap with other fixtures.  In some 
cases, it may be desirable to set two or more same type fixtures to the same Start Address.  In 
this case, the fixtures will be slaved together and respond to the same data.  Because all 
fixtures see the same data, fixtures may be set to any address without concern for the order 
they are connected by the DMX cables.   
 

 

DMX Data Connection 

This fixture uses 3 pin XLR type connectors and shielded twisted pair cable approved for 
EIA-422/EIA485 use.  Fixtures are connected in Daisy Chain topography:  Connection is 
made from the controller to the DMX-IN of the first light, then from the DMX-OUT to the 
DMX-IN of the next light and so on.  Only one data source can be on a chain and no 
branching is allowed.  The physical order in which the fixtures are connected is not 
important, use the most convenient.  

 
 
 
 
 
 
 
 

 

Data Terminator 

A Data Terminator can be connected to the DMX-OUT of the last fixture 
to reduce the effects of signal noise; it is not required for all installations. 
To make a Terminator, connect a 120-ohm ¼ watt resistor across pin 2, 
Data Negative (S-) and pin 3, Data positive (S+). A qualified technician 
can determine if a Data Terminator is needed. 

 

Adapter

 

5-to-3 pin 

Systems using 5 pin DMX interfaces can be accommodated by purchasing 3-to-5 pin 
adapters or building adapter cables.  Numbers designating each pin can be found on 
connectors.  Converting between the two XLR types is done in a pin-to-pin fashion.   
Connect the shields to pin 1, then connect pin 2 to pin 2 and pin 3 to pin 3, regardless of 
either connector’s gender or pin count.  No connection is made to Pins 4 & 5. 
 
 
 
 

DMX-OUT

1

- Ground

- Signal (-)
- Signal (+)

XLR Connector - Socket:

 

DMX-IN



- Ground
- Signal (-)
- Signal (+)

XLR Connector - Plug:

Содержание DL-LEDPANEL36C/B

Страница 1: ...RGB LEDS DL LEDPANEL36C W White with RGB LEDS DL LEDPANEL36W B Black with White Amber LEDS DL LEDPANEL36W W White with White Amber LEDS DL LEDPANEL36UV B Black with UV LEDS V2 0 This manual contains i...

Страница 2: ...e price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an R...

Страница 3: ...andalone Program 9 Setting Master Slave 9 P x y Standalone Program Chart RGB models only 9 DMX 512 Control 10 DMX Data Connection 10 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 11 DMX C...

Страница 4: ...ient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Auto Ranging 100 265vAC 50 60Hz Rated Power 40W Fuses Internal Ra...

Страница 5: ...f the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non...

Страница 6: ...justable base which allows the panel to be tilted at different desired angles Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixtur...

Страница 7: ...out cables This allows the units to receive data either from the master unit or the DMX controller Data wiring is explained in more detail in the DMX Data Connection section of this manual Example Bl...

Страница 8: ...ew settings wait 10 seconds The three digit display is the DMX512 Start Address and the P x y display is the selected internal program Setting the Start Address for DMX512 Control 1 When a DMX signal...

Страница 9: ...aster unit P x y Standalone Program Chart RGB models only X Program Y Option P0 Black out Brightness level of 0 no output P1 Static Red Brightness lowest 1 to brightest at 9 P2 Static Green Brightness...

Страница 10: ...le approved for EIA 422 EIA485 use Fixtures are connected in Daisy Chain topography Connection is made from the controller to the DMX IN of the first light then from the DMX OUT to the DMX IN of the n...

Страница 11: ...tween fixtures so the second Start Address is set to DMX channel 4 and that fixture occupies channels 4 thru 6 The third fixture will be addressed 4 3 7 and occupy channels 7 thru 9 The last fixture i...

Страница 12: ...ity of Green CH 3 Blue Sets relative intensity of Blue Channel Function 1 UV set 1 0 255 2 UV set 2 0 255 3 UV set 3 0 255 CH 1 Red DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 G...

Страница 13: ...UV LEDS in set 2 CH 3 UV Sets relative intensity of UV LEDS in set 3 CH 1 White DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 White DMX Value Function 0 No Output 1 255 Intensity...

Страница 14: ...e a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description C...

Страница 15: ...is sent all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to ide...

Страница 16: ...16 10900 Palmbay Drive Orlando FL 32824 U S A www techni lux com...

Отзывы: