background image

 

8

Operation Modes (LED Segment Display) 

The following refers to the different modes that are available on this fixture via the LED Segment 
Control Panel display. All functions are selectable from the display menu located at the back of 
the fixture using the two push buttons, A and B. “A” is on the left, “B” is on the right. 
 
 

Description of Display and Button Functions 

 

 

 
  
 

Display Panel Navigation 

Use the control panel located on the rear of the fixture to access its settings.  Press button “A” 
until the desired digit to modify is flashing.  Press button “B” to modify the flashing digit.  To exit 
and save new settings, wait 10 seconds. The three digit display is the DMX512 Start Address 
and the P(x,y) display is the selected internal program. 

 
 

Setting the Start Address for DMX512 Control 

1) When a DMX signal is present the fixture will respond to three channels of DMX 
beginning with the selected Start Address.  If no signal is present the unit will run the 
selected internal program.  
2) Press button “A” to select a digit to edit, current selection will blink. 
3) Press button “B” to change the value of the digit. 
4) Valid DMX address are from 1 to 510. Refer below to the DMX 512 Control section for 
a more detailed explanation about selecting proper DMX start addresses. 
5) To exit this mode, simply wait 10 seconds without pressing any buttons. The display 
will stop flashing the new settings will be saved. 

 
 

 

 

Содержание DL-LEDPANEL36C/B

Страница 1: ...RGB LEDS DL LEDPANEL36C W White with RGB LEDS DL LEDPANEL36W B Black with White Amber LEDS DL LEDPANEL36W W White with White Amber LEDS DL LEDPANEL36UV B Black with UV LEDS V2 0 This manual contains i...

Страница 2: ...e price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an R...

Страница 3: ...andalone Program 9 Setting Master Slave 9 P x y Standalone Program Chart RGB models only 9 DMX 512 Control 10 DMX Data Connection 10 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 11 DMX C...

Страница 4: ...ient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Auto Ranging 100 265vAC 50 60Hz Rated Power 40W Fuses Internal Ra...

Страница 5: ...f the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non...

Страница 6: ...justable base which allows the panel to be tilted at different desired angles Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixtur...

Страница 7: ...out cables This allows the units to receive data either from the master unit or the DMX controller Data wiring is explained in more detail in the DMX Data Connection section of this manual Example Bl...

Страница 8: ...ew settings wait 10 seconds The three digit display is the DMX512 Start Address and the P x y display is the selected internal program Setting the Start Address for DMX512 Control 1 When a DMX signal...

Страница 9: ...aster unit P x y Standalone Program Chart RGB models only X Program Y Option P0 Black out Brightness level of 0 no output P1 Static Red Brightness lowest 1 to brightest at 9 P2 Static Green Brightness...

Страница 10: ...le approved for EIA 422 EIA485 use Fixtures are connected in Daisy Chain topography Connection is made from the controller to the DMX IN of the first light then from the DMX OUT to the DMX IN of the n...

Страница 11: ...tween fixtures so the second Start Address is set to DMX channel 4 and that fixture occupies channels 4 thru 6 The third fixture will be addressed 4 3 7 and occupy channels 7 thru 9 The last fixture i...

Страница 12: ...ity of Green CH 3 Blue Sets relative intensity of Blue Channel Function 1 UV set 1 0 255 2 UV set 2 0 255 3 UV set 3 0 255 CH 1 Red DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 G...

Страница 13: ...UV LEDS in set 2 CH 3 UV Sets relative intensity of UV LEDS in set 3 CH 1 White DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 White DMX Value Function 0 No Output 1 255 Intensity...

Страница 14: ...e a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description C...

Страница 15: ...is sent all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to ide...

Страница 16: ...16 10900 Palmbay Drive Orlando FL 32824 U S A www techni lux com...

Отзывы: