used solely for a 0% to 100% switching.  Before applying power to a fixture, check that the 
fixture’s input voltage matches the power source voltage.  Consult a qualified electrician if there 
are any concerns about proper connection to power. 
 

Mounting 

Always consult a qualified professional when rigging.  Consider access for routine maintenance 
when selecting a mounting position. This fixture may be mounted in any position provided there 
is adequate room for movement and ventilation. Mount the fixture securely using the two 
mounting holes provided on both sides of the base. This fixture features an adjustable base 
which allows the panel to be tilted at different desired angles. Always keep cords out of the way, 
thus preventing any trip hazards. Secure all cables properly. Do not mount where the fixture will 
be exposed to heavy water fall, high humidity, extreme temperature changes or restricted 
ventilation.  Do not obstruct any of the heat sink vents.  
 

Optional Mounting Bracket 

 

There is an optional mounting omega bracket available 
that allows the use of a standard truss clamp to be 
mounted to this fixture. This mounting bracket must be 

purchased separately if needed. It provides a ½” sized clamp mounting hole. 
Order code: CL-OMEGA3 
 
 

Basic Reference 

 
 
Adjustable Bracket 
Knobs 
 
 
 
 
 
 
 
 
Female  XLR  3-pin    

   

 

Data Output Cable 
 
Male XLR 3-pin 
Data Input Cable 

 

 

     

                                

                         

                 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A & B Setting  
Push Buttons 

Power Input Cable                                                                                       
                                                                                                            Segment LED Display 

Содержание DL-LEDPANEL36C/B

Страница 1: ...RGB LEDS DL LEDPANEL36C W White with RGB LEDS DL LEDPANEL36W B Black with White Amber LEDS DL LEDPANEL36W W White with White Amber LEDS DL LEDPANEL36UV B Black with UV LEDS V2 0 This manual contains i...

Страница 2: ...e price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or Techni Lux directly to obtain an R...

Страница 3: ...andalone Program 9 Setting Master Slave 9 P x y Standalone Program Chart RGB models only 9 DMX 512 Control 10 DMX Data Connection 10 Data Terminator 10 Adapter 5 to 3 pin 10 DMX Start Address 11 DMX C...

Страница 4: ...ient temperature 105 F 40 C Min distance to flammable surface 3 3ft 1m Min distance to illuminated surface 1ft 0 3m Electrical Voltage Auto Ranging 100 265vAC 50 60Hz Rated Power 40W Fuses Internal Ra...

Страница 5: ...f the nature of the return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non...

Страница 6: ...justable base which allows the panel to be tilted at different desired angles Always keep cords out of the way thus preventing any trip hazards Secure all cables properly Do not mount where the fixtur...

Страница 7: ...out cables This allows the units to receive data either from the master unit or the DMX controller Data wiring is explained in more detail in the DMX Data Connection section of this manual Example Bl...

Страница 8: ...ew settings wait 10 seconds The three digit display is the DMX512 Start Address and the P x y display is the selected internal program Setting the Start Address for DMX512 Control 1 When a DMX signal...

Страница 9: ...aster unit P x y Standalone Program Chart RGB models only X Program Y Option P0 Black out Brightness level of 0 no output P1 Static Red Brightness lowest 1 to brightest at 9 P2 Static Green Brightness...

Страница 10: ...le approved for EIA 422 EIA485 use Fixtures are connected in Daisy Chain topography Connection is made from the controller to the DMX IN of the first light then from the DMX OUT to the DMX IN of the n...

Страница 11: ...tween fixtures so the second Start Address is set to DMX channel 4 and that fixture occupies channels 4 thru 6 The third fixture will be addressed 4 3 7 and occupy channels 7 thru 9 The last fixture i...

Страница 12: ...ity of Green CH 3 Blue Sets relative intensity of Blue Channel Function 1 UV set 1 0 255 2 UV set 2 0 255 3 UV set 3 0 255 CH 1 Red DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 G...

Страница 13: ...UV LEDS in set 2 CH 3 UV Sets relative intensity of UV LEDS in set 3 CH 1 White DMX Value Function 0 No Output 1 255 Intensity Off to Full On CH 2 White DMX Value Function 0 No Output 1 255 Intensity...

Страница 14: ...e a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold separately Order Code Description C...

Страница 15: ...is sent all channels are transmitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to ide...

Страница 16: ...16 10900 Palmbay Drive Orlando FL 32824 U S A www techni lux com...

Отзывы: