9
Setting P(x,y) Standalone Program
1) When there is no DMX signal present the fixture will run the selected Standalone
Program.
2) Pressing the “A” button 4 times advances to the P(x,y) Standalone Program display.
P(x,y) signifies: Program x, Option y. Reference the P(x,y) chart for details.
3) Press button “B” to edit the flashing digit, either Program Number x or Program Option
y.
4) To exit selected mode, simply wait 10 seconds without pressing any buttons. The
display will stop flashing and the new settings will be saved.
Setting Master/Slave
1) Master/Slave can only be used when no DMX signal is connected to the fixtures.
Choose one unit to be the Master and set the DMX Start Address to 001.
2) Set all the other units to be Slaves, by setting them to any other DMX address, other
than 001.
3) The Slave units will follow the Standalone Program selected on the Master unit.
P(x,y) Standalone Program Chart (RGB models only)
X (Program)
Y (Option)
P0 - Black out
Brightness level of 0, no output
P1 - Static Red
Brightness – lowest 1 to brightest at 9
P2 - Static Green
Brightness – lowest 1 to brightest at 9
P3 - Static Yellow
Brightness – lowest 1 to brightest at 9
P4 - Static Blue
Brightness – lowest 1 to brightest at 9
P5 - Static Pink
Brightness – lowest 1 to brightest at 9
P6 - Static Cyan
Brightness – lowest 1 to brightest at 9
P7 - Static White
Brightness – lowest 1 to brightest at 9
P8 - Multi-Color Chasing
Speed – from slowest 1 to fastest at 9
P9 - Multi-Color Fading
Speed – from slowest 1 to fastest at 9
PA - Multi-Color Flashing
Speed – from slowest 1 to fastest at 9
PB - Multi-Color Flashing
Speed – from slowest 1 to fastest at 9
PC - Auto-Run
Speed – from slowest 1 to fastest at 9
Note:
The standalone programs are mainly for the RGB models. On the White/Amber
and UV models, these settings just appear as different output levels since all the leds are
UV only or White/Amber. It may still be useful for the black out, chasing and fading
effects.