AIMA3000.FRAS Product User Manual
Technetix Group Limited
•
technetix.com
May/2016 - Version 1.0
36
Table 6-2 Port Configuration Parameter Description
Items
Sub Items
Effect and
configuration method
Configuration
Port Information
Slot
-
-
Module Type
-
-
Port
-
-
Status
Optical Input Status
Monitor the input optical signal
status; on the alarm page, the
operator can change the input
port monitoring upper/lower
limit and alarm level.
-
AGC Status
Under normal circumstances,
the AGC indicator is green.
When the AGC automatic
regulation exceeds the
adjustable range, the red status
indicator will be shown.
-
AGC Reference
AGC reference level when the
module is working under the
AGC status
-
Configuration
Input Wavelength
Changeable manual input
1260~1620 nm
Output Gain Type
Select the MGC/AGC
working mode
MGC/AGC
Out Gain Control
Factory setting 10 dB
0~20 dB
Slope Control
Output RF signal
slope regulation
0~7 dB
Alarm Setting
Input Status Alarm
Enable major alarm
Enable minor alarm
Disable alarms
Enable major
Enable minor
Disable
AGC Status Alarm
-
-
Critical High
Alarm level setting;
Adjustable alarm parameters
Warning High
Warning Low
Critical Low
Dead band