Select
“Port”
from the left column under the FRAS to go the module’s configuration page.
Figure 6-2
In the status window following parameters are shown:
In the configuration screen following parameters can be configured:
Parameter
Description
Factory default setting (bold) and range if
applicable
Optical Input Status Alarm
Indicate if the optical input is within
portioning threshold parameters.
Enable Major
Enable Minor
Disable
AGC Status Alarm
Indicate that AGC is enabled and operating
in range.
Enable Major
Enable Minor
Disable
Parameter
Description
Input Wavelength
User configurable field to indicate at which optical wavelength the FRAS is operating on. Use to
configure CWDM / DWDM systems.
Output Gain Type
To set operational mode between Manual gain control (MCG) and Automatic gain control (AGC)
Output Gain Control
Set the output gain value.
Slope Control
RF output tilt can be set up to 7 dB slope