7 Troubleshooting
7.1 Indicator for determining faults
If there is a fault, the operator can use the status LEDs to determine the location and condition of the fault as shown in the
following table:
Alarm light status
Common faults
Trouble Shooting
Input optical port status is orange
Input port optical power slightly low
Clean the optical port and fibre end,
measure the input optical power to ensure
that the input optical power is within the
normal range. If this fault still exists when
the input optical power is normal, contact
Technetix Technical Support Staff.
Input optical port status is red
Input port optical power too high/too low
Measure the input optical power to ensure
that the input optical power is within the
normal range. If this fault still exists when
the input optical power is normal, contact
Technetix Technical Support Staff.
STAT is Red
Input optical power abnormal
Bias current abnormal
Contact the Technetix Technical
Support Staff.
Power failure
Contact the Technetix Technical
Support Staff.
Temperature too high
Reduce the room temperature. If the room
temperature is normal, contact Technetix
Technical Support Staff.