6.7 Redundancy Configuration and Alarms (for FRAR only)
Click on
”Modules”
→
”FRAR-S”
(the module name), the port numbers and
”Redundancy”
button will appear. The port
configuration pages and alarm pages are completely same to FRAS.
Click on ”Redundancy” on the left, the redundancy configuration page will appear.
In the box of ”Redundancy Information”, you can check not only the local module’s slot number and module type, but also
the peer module’s IP address, slot number and serial number.
In ”Unit Redundancy Status” box, ”Redundancy Alarm” indicator and ”Redundancy Status” show the module’s redundancy status.
You can configure the module’s redundancy in the box ”Unit Redundancy Configuration”:
”Redundancy Enable” is to enable or disable the function of redundancy of this module;
”Work Mode” is to set this module to work in primary or secondary mode;
”Revert Enable” is to set whether the primary path will be reconnected when its signal gets normal.
”Wait to Restore Time” is the revert delay of the primary path when it gets normal.
”Redundancy Alarm” is to set the alarm level as major, minor or disable.
In the box of ”Port Redundancy Information”, you can enable or disable each port’s redundancy, set their local status alarm
level and configuration alarm level individually.
Please click on ”Submit” to save your configurations whenever you make new settings on them.