4.
SET UP INSTRUCTIONS
4.1 Mounting & Connection
The TS9800 Series Piezo Jet Valve should be used on an automated XYZ
table. It is very important that the valve is mounted on the Z-axis gantry, in
a secure manner, that will not allow loosening during dispense operation.
Mount the valve to the XYZ table bracket through the two tap holes (M4).
To prevent rust, it is recommended the bracket be made of stainless steel,
galvanized steel, or non-ferrous metals. The screwing depth is about 6 mm.
The
connection of the
TS9800 Piezo Jet Valve
to the
TS980 Smart
Controller
is done via the 3-pin plug and the 6-pin plug on the top of the
valve. The plugs are protected against mix-up by having different
number of pins. After connecting, the plug must be locked in place by
turning the locking nut on the cable’s mating connector a quarter of a
turn in a clockwise direction.
The 3-pin cable supplies the power for the piezo stack from 0 VDC to
100 VDC (bipolar operation). The 6-pin cable transfers the data of the
integrated sensor inside the valve. Disconnection is done by first rotating
the locking nut on the cable’s mating connector a quarter of a turn in a
counterclockwise direction, then gently pulling the connector axially
backwards.
Caution
:
Never disconnect the cables from the valve while
the system is still dispensing, this will lead to damage to the valve and
the control unit. If the system is not operating, you can disconnect the
valve and the control unit.
Figure 2: Mounting
Mount the bracket to the two sets of
mounting holes:
2x thread M4
Thread depth: 6 mm
Distance to center: 45 mm
2x ø4mm dowel pin holes
Hole depth: 6mm
Distance to center: 31 mm