![TECHCON TS980 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/techcon/ts980/ts980_user-manual_1066385024.webp)
7.
VALVE SETUP AND CLEANING
7.1
Valve Removal
1.
Turn off or disconnect the fluid pressure to the material syringe or fluid
supply line from the material reservoir.
2.
Remove the material syringe from the luer-lock fitting. Make sure to
use an 8 mm open-jaw hex wrench to hold the fitting tight while
removing the syringe.
3.
Switch off the control unit.
4.
Disconnect all valve cables.
5.
Remove the valve from the XYZ table.
6.
The valve can now be taken apart for cleaning. Refer to section 7.3 for
cleaning instructions.
7.
After replacing the valve or control unit, repeat section 4.2 for setup
and section 4.3 for nozzle calibration.
7.2 Installation of New Nozzle Insert
1.
Turn off or disconnect pressure to the material syringe.
2.
Unscrew the nozzle unit from the fluid manifold using the nozzle
adjustment tool.
3.
Unscrew the nozzle bushing/insert assembly from the nozzle
adjustment nut using the nozzle installation tool.
24
Jet Valve Dispensing System User Guide
TS9800
& TS980