6.
Use the provided 2 mm hex key to remove two holding screws (5) and
carefully pull the fluid manifold assembly (4) from the upper valve body
(1).
Attention:
When re-assembling the fluid manifold assembly to upper
valve body after cleaning, use the provided 2 mm hex wrench to tighten
the two holding screws evenly (torque the screws to 5 - 6 lbf-in or
0.6 – 0.7 N-m).
Attention:
The tappet seal (3) usually remains on the tappet (red
arrow), however if it’s stuck in the fluid manifold, the tappet seal can be
removed by inserting the provided tappet seal tool from the fluid
manifold’s outlet hole and slowly pushing upward on the seal.
Follow the steps below to re-assemble the tappet seal after cleaning.
Caution:
If the seal is installed backward, it will cause leakage.
a.
Top side of tappet seal.
28
Jet Valve Dispensing System User Guide
TS9800
& TS980