10.4 DB-15 I/O Port Functions
Note:
Digital output requires a pull up resistor to the positive supply
of the receiving device.
Note:
DI: Digital Input
DO: Digital Output
PW: Power
DB-15 CONNECTOR
PIN
FUNCTION
I/O
TYPE
DESCRIPTION
LEVELS
1
VOLTAGE OUT
O
PW
Reference – 24VDC
-
2
NC
-
-
-
-
3
HEATER TEMP
STATUS
O
DI
Signal when fluid manifold heater
has reached targeted temperature
0V
Target reached
0-24V Pulse Target not
reached
4
ERROR OUT
O
DI
Signal if any error or warning is
present
0V Error/Warning Active
24V No Error/Warning has
occurred
5
NC
-
-
-
-
6
TRIGGER OUT
O
DI
Trigger to outside device. It’s
square wave that is high when
tappet lifts, low when tappet
closes
+V When tappet lifts
0V When tappet closes
7
TRIGGER IN
I
DI
Trigger dispensing process from
outside device such as external
robot or PLC
24V Valve Idling
0V Valve Dispensing
8
GROUND COMMON
O
PW
Reference – GND
-
9
NC
-
-
-
-
10
NC
-
-
-
-
11
VALVE OVERTEMP
O
DI
Signal
when
the
Piezo
temperature has exceeded +85°C
operating limit
0V Temperature exceeded
24V Temperature is within
range
12
NC
-
-
-
-
13
NC
-
-
-
-
14
NC
-
-
-
-
15
GROUND COMMON
O
PW
Reference – GND
-
1
8
15
9
56
Jet Valve Dispensing System User Guide
TS9800
& TS980