TECDrive TEC-3 User Guide Revision 1.20 

 

www.tecmotors.co.uk/tecdrive 

17

 

 

6

 
Pa
ra

m

e

ter

6.

 

Parameters 

6.1.

 

Standard Parameters 

Par. 

Description 

Minimum 

Maximum 

Default 

Units 

P-01 

Maximum Frequency / Speed Limit 

P-02 

500.0 

50.0 (60.0) 

Hz / RPM 

Maximum output frequency or motor speed limit 

 Hz or RPM. If P-10 >0, the value entered / displayed is in RPM 

P-02 

Minimum Frequency / Speed Limit 

0.0 

P-01 

0.0 

Hz / RPM 

Minimum speed limit 

 Hz or RPM. If P-10 >0, the value entered / displayed is in RPM 

P-03 

Acceleration Ramp Time 

0.00 

600.0 

5.0 

Acceleration ramp time from zero Hz / RPM to base frequency (P-09) in seconds. 

P-04 

Deceleration Ramp Time 

0.00 

600.0 

5.0 

Deceleration ramp time from base frequency (P-09) to standstill in seconds. When set to 0.00, the value of P-24 is used. 

P-05 

Stopping Mode / Mains Loss Response 

Selects the stopping mode of the drive, and the behaviour in response to a loss of mains power supply during operation. 

Setting 

On Disable 

On Mains Loss 

Ramp to Stop (P-04) 

Ride Through (Recover energy from load to maintain operation) 

Coast 

Coast 

Ramp to Stop (P-04) 

Fast Ramp to Stop (P-24), Coast if P-24 = 0 

Ramp to Stop (P-04) with AC Flux Braking

 

Fast Ramp to Stop (P-24), Coast if P-24 = 0

 

P-06 

Energy Optimiser 

0 : Disabled

 

1: Enabled

. When enabled, the Energy Optimiser attempts to reduce the overall energy consumed by the drive and motor by 

reducing the output voltage during constant speed, light load operation. The Energy Optimiser is intended for applications where 
the drive may operate for some periods of time with constant speed and light motor load, whether constant or variable torque. 

P-07 

Motor Rated Voltage / Back EMF at rated speed (PM / BLDC) 

250 / 500 

230 / 400 

For Induction Motors, this parameter should be set to the rated (nameplate) voltage of the motor (Volts). 
For Permanent Magnet or Brushless DC Motors, it should be set to the Back EMF at rated speed. 

P-08 

Motor Rated Current 

Drive Rating Dependent 

This parameter should be set to the rated (nameplate) current of the motor 

P-09 

Motor Rated Frequency 

10 

500 

50 (60) 

Hz 

This parameter should be set to the rated (nameplate) frequency of the motor 

P-10 

Motor Rated Speed 

30000 

RPM 

This parameter can optionally be set to the rated (nameplate) RPM of the motor. When set to the default value of zero, all speed 
related parameters are displayed in Hz and the slip compensation (where motor speed is maintained at a constant value regardless 
of applied load) for the motor is disabled. Entering the value from the motor nameplate enables the slip compensation function, and 
the TECDrive display will now show motor speed in RPM. All speed related parameters, such as Minimum and Maximum Speed, 
Preset Speeds etc. will also be displayed in RPM. 

Note

 If P-09 value is changed, P-10 value is reset to 0 

P-11 

Low Frequency Torque Boost Current 

0.0 

Drive 

Dependent

 

Drive 

Dependent 

Low frequency torque can be improved by increasing this parameter. Excessive boost levels may however result in high motor 
current and increased risk of tripping on Over Current or Motor Overload (refer to section 10.1) 
This parameter operates in conjunction with P-51 (Motor Control Mode) as follows :- 

P-51 

P-11 

 

Boost is automatically calculated according to autotune data 

>0 

Voltage boost =  P-11 x P-07.This voltage is applied at 0.0Hz, and linearly reduced until P-09 / 2 

All 

Voltage boost =  P-11 x P-07.This voltage is applied at 0.0Hz, and linearly reduced until P-09 / 2 

2, 3, 4 

All 

Boost current level = 4*P-11*P-08   

For IM motors, when P-51 = 0 or 1, a suitable setting can usually be found by operating the motor under very low or no load 
conditions at approximately 5Hz, and adjusting P-11 until the motor current is approximately the magnetising current (if known) or 
in the range shown below. 
Frame Size 1 : 60 

 80% of motor rated current 

Frame Size 2 : 50 

 60% of motor rated current 

Frame Size 3 : 40 

 50% of motor rated current 

Frame Size 4 : 35 

 45% of motor rated current 

P-12 

Primary Command Source 

0: Terminal Control

. The drive responds directly to signals applied to the control terminals. 

1: Uni-directional Keypad Control

.  The drive can be controlled in the forward direction only using the internal keypad, or an 

external remote Keypad. 

2: Bi-directional Keypad Control

. The drive can be controlled in the forward and reverse directions u using the internal keypad, or 

an external remote Keypad. Pressing the keypad START button toggles between forward and reverse. 

3: Modbus Network Control. 

Control via Modbus RTU (RS485) using the internal Accel / Decel ramps

 

4: Modbus Network Control. 

Control via Modbus RTU (RS485) interface with Accel / Decel ramps updated via Modbus

 

5: PI Control. 

User PI control with external feedback signal

 

6: PI Analog Summation Control. 

PI control with external feedback signal and summation with analog input 1 

7: CAN open Control

. Control via CAN (RS485) using the internal Accel / Decel ramps 

8: CAN open Control

. Control via CAN (RS485) interface with Accel / Decel ramps updated via CAN 

9: Slave Mode

. Control via a connected Invertek drive in Master Mode. Slave drive address must be > 1. 

NOTE 

When P-12 = 1, 2, 3, 4, 7, 8 or 9, an enable signal must still be provided at the control terminals, digital input 1 

Содержание TECDrive TEC -3-120070-101 Series

Страница 1: ...uide Revision 1 20 www tecmotors co uk tecdrive 1 1 Quick Start Up TECDrive User Guide IP20 IP66 NEMA 4X AC Variable Speed Drive 0 37 22kW 0 5 30HP 110 480V Distributed by TEC Electric Motors www tecm...

Страница 2: ...TECDrive TEC 3 User Guide Revision 1 20 2 www tecmotors co uk tecdrive 1 Quick Start Up Di and Operating Instructions...

Страница 3: ...ions 14 4 9 Motor Thermal overload Protection 15 4 10 EMC Compliant Installation 15 4 11 Optional Brake Resistor 15 5 Operation 16 5 1 Managing the Keypad 16 5 2 Operating Displays 16 5 3 Changing Par...

Страница 4: ...g from transport receipt of delivery installation or commissioning The manufacturer also accepts no liability for damage or consequences resulting from inappropriate negligent or incorrect installatio...

Страница 5: ...normally will be limited by the fuses or MCB Suitably rated fuses or MCB should be fitted in the mains supply to the drive according to any local legislation or codes Do not carry out any work on the...

Страница 6: ...before connecting the supply 9 5 EMC Filter Disconnect 28 7 Check the supply cable and motor cable for faults or short circuits 8 Route the cables 9 Check that the intended motor is suitable for use...

Страница 7: ...to Stop Connect a potentiometer 5k 10k between terminals 5 6 and 7 as shown o Adjust the potentiometer to vary the speed from P 02 0Hz default to P 01 50 60 Hz default Quick Start IP66 Switched Switc...

Страница 8: ...1 0 75 1 4 3 1 TEC 3 120070 1F1 TEC 3 120070 101 1 5 2 7 1 TEC 3 220070 1F4 TEC 3 220070 104 1 5 2 7 2 TEC 3 220105 1F4 TEC 3 220105 104 2 2 3 10 5 2 N A TEC 3 320153 104 4 0 5 15 3 3 200 240V 10 3Pha...

Страница 9: ...e suitable for use in pollution degree 1 environments according to IEC 664 1 For pollution degree 2 or higher environments drives should be mounted in a suitable control cabinet with sufficient ingres...

Страница 10: ...section 9 1 The drive must be mounted vertically on a suitable flat surface The minimum mounting clearances as shown in the table below must be observed The mounting site and chosen mountings should b...

Страница 11: ...nduit installations the conduit entry holes require standard opening to the required sizes specified per the NEC Not intended for installation using rigid conduit system Power Isolator Lock Off On the...

Страница 12: ...d must be connected to system ground Ground impedance must conform to the requirements of national and local industrial safety regulations and or electrical codes The integrity of all ground connectio...

Страница 13: ...mended to be installed in the supply line for drives where any of the following conditions occur o The incoming supply impedance is low or the fault level short circuit current is high o The supply is...

Страница 14: ...STOP Run in Hand 0 4 Run in Hand Speed controlled from the Local POT Run in Auto 0 Speed controlled using Analog input 2 e g from PLC with 4 20mA signal Run in Speed Control STOP Run in PI Control 5 1...

Страница 15: ...ry Supply Cable Type Motor Cable Type Control Cables Maximum Permissible Motor Cable Length C16 Shielded1 Shielded1 5 Shielded4 1M 5M7 C2 Shielded2 Shielded1 5 5M 25M7 C3 Unshielded3 Shielded2 25M 100...

Страница 16: ...nds Press and hold the Navigate key 2 seconds To reset parameter values to their factory default settings press and hold Up Down and Stop buttons for 2 seconds The display will show Drive is enabled r...

Страница 17: ...from the motor nameplate enables the slip compensation function and the TECDrive display will now show motor speed in RPM All speed related parameters such as Minimum and Maximum Speed Preset Speeds e...

Страница 18: ...ncy 4 32 8 kHz Sets maximum effective switching frequency of the drive If rEd is displayed when the parameter is viewed the switching frequency has been reduced to the level in P00 32 due to excessive...

Страница 19: ...Power On or Reset the drive will automatically start if Digital Input 1 is closed To Following a trip the drive will make up to 5 attempts to restart at 20 second intervals The numbers of restart att...

Страница 20: ...mmunication An suffix means that the drive will coast stop output immediately disabled but will not trip P 37 Access Code Definition 0 9999 101 Defines the access code which must be entered in P 14 to...

Страница 21: ...3 Advanced Parameters Par Description Minimum Maximum Default Units P 51 Motor Control Mode 0 5 0 0 Vector speed control mode 1 V f mode 2 PM motor vector speed control 3 BLDC motor vector speed contr...

Страница 22: ...cess data output outgoing process data TX PDO1 for CANopen PO1 PO2 PO3 PO4 P00 23 Accumulated time with heatsink 85 C Hours Total accumulated hours and minutes of operation above heatsink temp of 85 C...

Страница 23: ...T STOP P 24 When both inputs are active simultaneously the drive stops using Fast Stop Ramp Time P 24 E TRIP External Trip input which must be Normally Closed When the input opens the drive trips show...

Страница 24: ...ntrol Mode P 12 3 4 7 8 or 9 P 15 DI1 DI2 DI3 AI2 DI4 AI1 Diagram 0 1 0 1 0 1 0 1 0 STOP ENABLE FB REF Fieldbus Speed Reference Modbus RTU CAN Master Slave defined by P 12 14 1 STOP ENABLE PI Speed Re...

Страница 25: ...emperature U t Drive Under Temperature Th FLt Faulty Thermistor on Heat sink E trip External Trip 4 20 F 4 20mA fault Ph Ib Phase Imbalance P Loss Input Phase Loss Trip SC trp Communications Loss Trip...

Страница 26: ...gh Run Enable Bit 1 Low Decel Ramp 1 P 04 High Decel Ramp 2 P 24 Bit 2 Low No Function High Fault Reset Bit 3 Low No Function High Coast Stop Request 2 R W Modbus Speed reference setpoint 0 5000 Setpo...

Страница 27: ...8 15 3 25 200 240 10 V 3 Phase Input 3 Phase Output 1 0 37 0 5 3 4 6 6 8 8 2 3 1 0 75 1 5 6 10 10 8 8 4 3 1 1 5 2 9 5 16 15 8 8 7 2 1 5 2 8 9 16 15 8 8 7 100 2 2 2 3 12 1 16 17 5 8 8 10 5 50 3 4 5 20...

Страница 28: ...cording to section 4 3 Suitable Power and motor cables should be selected according to the data shown in section 9 2 and the National Electrical Code or other applicable local codes Motor Cable 75 C C...

Страница 29: ...sed over 10 C in order to start the drive 10 Factory Default parameters loaded 11 External trip E trip requested on digital input 3 Normally closed contact has opened for some reason If motor thermist...

Отзывы: