- 30 -
EO3-11070
MA-1650-4 SERIES
CONDITION
OPERATION
SFKC (Selective Function Key Code) PROGRAMMING
This operation is to determine the keyboard layout with the required keys and must be carried out first before any
other programming operation. If a RAM CLEAR has been operated prior to the SFKC programming, program only
the keys that require changes from the SFKC in the Standard Keyboard which has automatically been set by the
RAM Clear operation. (Standard Keyboards on pages 34 and 35)
The following keys that are minimum requirements for programming and registering operations must be installed
on the keyboard no matter what other keys may or may not be installed:
[C], [X] (or [@/FOR]), [ST], [AT/TL], [#], and Department Keys or [DP#]
CONDITION
After all Z & GTZ reports, or after RAM CLEAR, DATA CLEAR, or STATUS CLEAR
OPERATION
Mode Lock: BLIND
1. Enter 76, and depress the key to be [AT/TL] (Cash Media key). This declares the SFKC Programming Start
and at the same time sets the SFKC 76 on the key. From this step on, the depressed key will be [AT/TL].
2. Enter the SFKC (see the SFKC table on the following page), and depress the key that require the key name
of that SFKC. Repeat this step until all the required keys are set with their own SFKC’s. Each key on the
keyboard must correspond to one SFKC, except for SFKC 96 (PLU Preset-code Keys). If in this step, a
key is simply depressed without a prior SFKC entry, the SFKC that has been pre-programmed on that key
is displayed at the AMOUNT portion.
NOTES:
1) The entered SFKC is displayed at the AMOUNT portion of the display.
2) If a wrong code has been entered and the key has also been depressed (i.e. a wrong SFKC
has been set on a key), enter the correct SFKC and depress the key. The code entered last
will be effective.
3) If “0” is entered as SFKC, the key will be dead and its memory will also be closed.
4) Each of the keys programmed in this step will have its memory (if any) opened automatically.
5) The [C] key, if once set with SFKC 95, may be used to clear an error, but not to clear and SFKC
entry. If any SFKC is entered and the [C] key is depressed, that SFKC will be set on the key
that was once the [C] key.
6) To designate the SFKC 100 for the [TAX] key (Manual Tax), operate the keys [1]
→
[0]
→
[0].
In this case, the [00] key is unavailable.
3. Depress the [AT/TL] key (the key set as [AT/TL] in Step 1) to end the SFKC programming operation. The