6. SYSTEM MODE
EO18-33011
(Revision Date: Mar. 30, 2004)
6.5 PARAMETER SETTING
6-24
6.5.16 KB-80 Optional Keyboard Connect Setting
With this parameter you can select whether or not the KB-80 optional keyboard is used. When
“<2>PARAMETER SET” appears, press the [PAUSE] key 16 times.
After selecting the KB-80 connection, press the [PAUSE] key.
NOTES:
1. When “KB80 CONNECT ON” is selected, the D-sub 9-pin RS-232C interface
cannot be used.
2. To make this parameter effective, the KB-80 optional keyboard is required.
6.5.17 Ribbon Near End Setting
With this parameter you can select the condition of ribbon near end detection. When
“<2>PARAMETER SET” appears, press the [PAUSE] key 17 times.
After selecting the ribbon near end condition, press the [PAUSE] key.
KB80 CONNECT OFF
KB80 CONNECT ON
KB80 CONNECT OFF
[RESTART]
[FEED]
Unavailable
Available
RBN NEAR END 70
RBN NEAR END 30
RBN NEAR END 70
[RESTART]
[FEED]
Ribbon near end is detected when the remaining
ribbon length is about 70 m.
Ribbon near end is detected when the remaining
ribbon length is about 30 m.
RBN NEAR END OFF
Ribbon near end is not detected.