INSTALLATION AND USE
Machine installation must be done by qualified personnel. All connections must be done in conformity with current
specifications and with respect for industrial accident prevention regulations.
Before connecting the power source to the mains, check that it is between 210 V and 250 V.
Mains receptacle
must be earthed.
Tables of lengths and sections
Mains used must always supply the required power.
In some applications extension cables are necessary to reach the work area. To ensure maximum power source
output, abide by the following tables showing the section of the extention cables vs. length.
WELDING STICK OF 3
,25 MM (1/8”) (140A-160 A) and TIG WELDING OF 200 A
10 mt (33 ft)
2,5 mmq (12 AWG)
20 mt (66 ft)
4 mmq (10 AWG)
30 mt (99 ft)
6 mmq (9 AWG)
NOTE: For different lengths, use a proportional section size.