20
7. Antisticking
If during
STICK or STICK + ARC FORCE
welding procedure the electrode sticks for a few seconds,
“ANTISTICKING”
will appear on the display and the output current drops to lmin, avoiding electrode overheating.
WHAT IF THE INVERTER DOESN’T WORK?
The welder doesn’t switch-on:
check the mains connection and the switch position (1).
Irregular electrode welding:
Check correct connection of the cable holder and earth clamp according to the electrode being used.
Check that the welding current is appropriate for the electrode and the piece to be welded.
Check that the electrodes are not wet or damaged.
Check that the weld piece is not excessively dirty, greasy, etc.
Check that the earth clamp is well connected to the weld piece.
The welder doesn’t generate the power required:
Check that the mains voltage is between 210V-250V (even during welding)
If extension cables are used, make sure that they conform to the table on page 10.
In TIG welding:
The torch spatters during welding:
Check that the torch and earth are correctly connected.
Check that gas is present and that the flow is sufficient.
Check that the weld piece is not greasy or dirty.
Check that the weld piece isn’t composed of alloys incompatible with the power source used.
Check that the electrode is the right colour for the material to be welded.
Check if too high a current setting is being used.
Duty Cycle too short:
Check that the fan is turning.
Check if the fan is blocked and that air circulates from the air grids.
Check if the working environment is too hot.
Содержание Ergus WIG 160 CDI
Страница 1: ...MANU 115 M TIG 00 INDUSTRIE LINE WIG 160 DCi CDI WIG 201 DCi CDI USER MANUAL...
Страница 23: ...23 BLOCK DIAGRAM WIG 160 DCi...
Страница 24: ...24 WIG 160 CDI...
Страница 25: ...25 WIG 201 DCi...
Страница 26: ...26 WIG 201 CDI...
Страница 27: ...27 REMOTE CONTROL CONNECTION DIAGRAM WIRING OF CONNECTORS...
Страница 29: ...29 WIG 160 DCi...
Страница 31: ...31 WIG 160 CDI...
Страница 33: ...33 WIG 201 DCi...
Страница 35: ...35 WIG 201 CDI...