background image

7

TEC-61201-1

 

Technical Manualе 

PRIZRAK-510, 520 v7

Table4.  

 

Immobilizer Programmable Output Functions

No.

Function 

Description

1

Security

Generation of a constant level signal when in Security mode

2

Arming impulse

(Security feature)

Generation of 0.8 sec impulse when entering the Security mode or triggering AntiHiJack feature

3

Disarming impulse

(Security feature)

Generation of 0.8 sec impulse when leaving the Security mode

4

Authentication pulse

Emitting 0.8 sec pulse after PIN code is entered or in Maintenance mode (1 second after the ignition has

been turned on).

5

Original alarm system panic

Generation of a constant level signal while original alarm system (if installed) is in alarm condition

6

Beeper panic

Generation of a 30 sec constant level signal in Security mode if one of the main zones (doors, hood, trunk) 

or any sensor is triggered. The signal stops after exiting the Security mode

7

Horn panic

Generation of a 30 sec impulse signal in Security mode if one of the main zones (doors, hood, trunk) is 

triggered or when arming/disarming the Security mode. This function applies to vehicles without integrated 

original alarm system. The signal stops after exiting the Security mode. This function can send an alarm 

signal to original horn of the vehicle

8

Doors, hood and trunk

Generation of a constant level signal if any of the preset doors, hood or trunk is triggered

9

Sensors ignoring

Constant level signal is generated while in Security mode if the trunk was opened via an original remote 

control or when Comfort feature is enabled. This function can disable sensors to prevent false alarms

10

Original buttons

Generation of a constant level signal when pressing a preset button of the vehicle

11

Ignition

Generation of a constant level signal when ignition is turned on (including engine startup)

12

АСС

Generation of a constant level signal when ACCs of the vehicle (1st key position; for some vehicles matches 

the ignition position) are on. The signal stops only after the key is out of the ignition lock. Can be used to 

power extra alarm systems or multimedia

13

Engine on

Generation of a constant level signal when the engine is on

14

Engine RPM

Generation of 1 impulse per second in proportion with engine crankshaft 20 rpm. RPM is estimate, not precise

15

Gearbox status

Generation of a constant level signal if transmission handle is in preset position (P, R, N, D*). For Easytronic 

gearbox the following positions are available: R, N, D*: automatic transmission – P, R, N, D*; manual 

transmission – only R

16

Vehicle is moving

Generation of a constant level signal if the speed exceeds some threshold value (differs for each vehicle, but 

generally the range is within 5 to 10 km/h)

17

Front parking sensors control

Generation of a constant level signal if the engine is on and the speed of the vehicle is less than 15 km/h

18

Rear parking sensors control

Generation of a constant level signal if the engine is on, transmission handle is in R-position, and the speed 

of the vehicle is less than 15 km/h

19

Moving speed

Generation of 1 impulse per second in proportion to 1 km/h of the vehicle speed. Speed value is 

estimate, not precise

20

Brake

Generation of a constant level signal when the brake pedal is pressed

21

Parking brake

Generation of a constant level signal when the vehicle is on hand brake

22

External lights

Generation of a constant level signal when external lights are on

23

Timer Channel (Comfort)

Generation of a constant level signal within 10-60 seconds after the Security mode is enabled. 

Time interval is set in increments of 10 seconds

24

Starter and test bus interlock

Generation of a constant level signal: if the bus is active, the signal will be on up to authentication; when 

AntiHiJack is triggered

25

26

Accelerator pedal interlock 

(enforcing a full stop)

Stops the vehicle if AntiHiJack feature was triggered provided the Safety Lock is enabled. Management of 

normally closed locking relay 

*

All handle positions for vehicle advancement (D, S, M, L, etc.).

Table5.  Immobilizer Programmable Input Functions

No.

Designation 

Description

1

Brake light status check

Brake light status check (default). Activated if the vehicle CAN bus does not have brake pedal position 

data (see Integrator files). In such cases Input 1 must be connected to the output of brake pedal 

terminal switch

2

Hood status check

If CAN bus does not have data about hood position, this input must be connected to the hood terminal 

switch

3

Driver’s door terminal switch

Only when the CAN bus is unaware of the driver’s door status (see Integrator files).

4

HCU-230 Hood locking

By sending an impulse to this input, the system can engage an extra hood lock via HCU-230. This 

feature is helpful if the Immobilizer is used with equipment provided by others 

5

Ignition check

The function applies only in cases when the correct data from CAN bus is not available. This situation 

may occur when certain vehicle circuits are jumpered. In this case Ignition control input is to be 

connected to the vehicle wire that has a constant level signal when the ignition is on. Connecting this 

input does not cancel ignition analysis via CAN bus. Ignition status is checked as ON when data is 

received by any informational channel (CAN bus or analog input)

Programming sequence

1. 

Turn the ignition on.

2. 

 Enter  PIN code, wait for confirmation.

If the vehicle has failed to travel 10 km after installation and 

factory default PIN code remained unchanged, it is allowed 

to use PIN code “2” for identity verification by pressing an 

integrated button.

Содержание PRIZRAK-510

Страница 1: ...510 v7 520 v7 T ECH NIC A L M A NUA L For smart cars smart car holders Immobilizer heart of auto theft protection sistem...

Страница 2: ...mmobilizer will follow its algorithms The driver s door was opened Upon entering the Guard mode AntiHiJack feature goes through a series of phases and in case if the Guard mode was not deactivated the...

Страница 3: ...e Wait for the confirming trill Maintenance mode Maintenance is an operation mode when all hijack protection and service functions of the Alarm are temporarily disabled The Alarm will notify of activa...

Страница 4: ...rolling on vehicles where CAN bus control is not available Please see Integrator files software product for information on vehicle specific connection features Pin No 6 Ground is connected to vehicle...

Страница 5: ...the steering wheel and steering wheel column joysticks buttons cruise control central unit control etc sequentially one after another Those buttons which after being pushed receive a response audible...

Страница 6: ...setting for PRIZRAK 520 1 4 1 1 maximum 2 high 3 low 4 minimum After the Immobilizer is installed adjusts the sensitivity 9 Hazard lights control algorithm 1 5 Set automatically but can be set manuall...

Страница 7: ...ange is within 5 to 10 km h 17 Front parking sensors control Generation of a constant level signal if the engine is on and the speed of the vehicle is less than 15 km h 18 Rear parking sensors control...

Страница 8: ...the brake pedal while the Immobilizer goes back to indication of the option number 7 Programming algorithm for function 10 Original buttons With the brake pedal pressed go to option 10 The Immobilizer...

Страница 9: ...y moment by turning off the ignition A trill will sound If no actions were taken within 60 seconds and brake pedal was released the Immobilizer will exit programming mode If the vehicle has travelled...

Страница 10: ...just the setting of option 3 by pressing the Programming button 2 times i e increase the option value by 2 increments 1 2 3 Immobilizer will acknowledge the selection by emitting a sequence of 3 audib...

Страница 11: ...ing PRIZRAK receives the information about the vehicle moving via CAN bus If the central unit was removed the relay will lock the engine using accelerometer once the vehicle starts moving yellow white...

Страница 12: ...l Manual PRIZRAK 510 520 v7 Use the picture to draw arrangement of alarm units This can help when trying to find specific units Keep this sketch out of the reach of third parties Immobilizer units arr...

Страница 13: ...arranty certificate 1 Connection diagram 1 Packing 1 Parameter Value Power supply voltage V 9 15 Maximum current consumption in standby mode mA 5 Maximum current consumption in standby mode mA 1200 fo...

Страница 14: ...14 TEC 61201 1 Technical Manual PRIZRAK 510 520 v7...

Страница 15: ...15 TEC 61201 1 Technical Manual PRIZRAK 510 520 v7...

Страница 16: ...Ltd The product is produced according to TU 4573 009 78025716 12 Certificate of conformityTS RU C RU OC13 B 01026 The product conforms to the requirements of the Technical reglament of Custom Union T...

Отзывы: