User Settings Configuration

Menu 2. User settings

No. Type

Factory 

default 

settings

Number of audible signals

1 Immobilizer

On

1 – ON

2 – OFF

2 AntiHiJack

3 AntiHiJack response delay

1

Range 1 to 10  1  –  100  m;  ...10  –  1000  m. Sets the 

distance until the engine lock

4

Audio confirmation of authentication by PIN-code

On

1 – ON

2 – OFF

5

Automatic deactivation of Maintenance mode

6 Activation of Central Lock while driving

Off

7 Deactivation of Central Lock after ignition is turned off
8 Automatic window roll up (Comfort feature)

On

Programming sequence

1. 

 Turn  the ignition on.

2. 

 Enter  PIN code, wait for confirmation.

3. 

Once the system has been powered, within 10 seconds enter 

the configuration menu by pressing the Programming button 

12 times. If your actions are correct, the Immobilizer will 

confirm it by 4 audible signals.

4. 

Select the option from the menu by pressing the Programming 

button a required number of times (equal to the number of the 

option). The Immobilizer will acknowledge the option number 

by a series of audible signals.

5. 

Go to option setting by pressing and holding the brake pedal. 

The Immobilizer will notify of the option status by a series of 

audible signals of a changing duration.

6. 

 Adjust  option  settings  by  pressing  the  Programming  button 

the number of times matching the number of steps from the 

current status to the required one. Please remember that from 

the last function the program will go to the first one.

7. 

 Release  the brake pedal. Now you can move to programming 

the next function or exit the programming mode.

8. 

 Go  to configuring another option by pressing the Programming 

button the number of times matching the number of steps 

from the current option to the required one. For example, to 

go from option 2 (AntiHiJack) to option 6 (Activation of Central 

Lock while driving) press the Programming button 4 times.

You can exit programming mode at any moment by turning off 

the ignition. A trill will sound. If no actions were taken within 

60 seconds and brake pedal was released, the Immobilizer will 

exit programming mode.

You can exit programming mode at any moment by turning off the 

ignition. A trill will sound. If no actions were taken within 60 seconds 

and brake pedal was released, the Immobilizer will exit programming 

mode.

• 

If the vehicle has travelled 10 km after installation, and 

factory default PIN code remained unchanged, it is 

allowed to use PIN code “2” for identity verification by 

pressing an integrated button.

• 

To change method of authentication (option 9) you must 

enter PUK-code: you can find it under the opaque cover 

on the plastic card. No audible signals are generated 

before entering the PUK-code. Afterwards  a  trill  will 

sound, and the system will indicate the option number.

• 

PUK-code as a means for changing the authentication 

method is not required if:

1. 

 the  vehicle travelled less than 10 km after installation 

of the Immobilizer (Speed Control is available).

2. 

 the  ignition was not active for more than 20 minutes 

after installation of the Immobilizer (Speed Control 

is not available)

Changing PIN code

1. 

 Turn  the ignition on.

2. 

 Enter  PIN code, wait for confirmation.

3. 

Press  the  Programming  button  10  times  within  14 seconds 

after the authentication. Wait for confirmation by 1 audible 

signal.

4. 

Set the new PIN code by using any combination of buttons. 

Now you can use the buttons. Pressing is confirmed by an 

audible signal.

5. 

Wait for confirmation by 1 audible signal.

6. 

 Re-enter  the new PIN code.

7. 

 Wait  for confirmation:

• 

2 audible signals and a sound trill mean that the PIN code 

has been changed and the Immobilizer has left the PIN 

code changing mode.

• 

Sound alert means that the PIN code has not been changed: 

An error occurred while entering a new PIN. Repeat PIN 

changing procedure starting from step 4.

You can exit the PIN code changing mode anytime by turning the 

ignition off.

• 

You cannot change PIN to «1» – a single push of a button.

Reassigning Programming Button

1. 

Reset all settings to factory default.

2. 

Run the Immobilizer interfacing procedure.

3. 

If analog steering wheel buttons are used please define them 

(see above for the description of this procedure).

4. 

In order to assign any of the buttons recognized by the 

Immobilizer as the Programming button, press the selected 

button and hold it for at least 5 seconds until a long audible 

signal is heard.

The Programming button can be assigned within 15 minutes after 

the Immobilizer interfacing with the vehicle.

Содержание PRIZRAK-510

Страница 1: ...510 v7 520 v7 T ECH NIC A L M A NUA L For smart cars smart car holders Immobilizer heart of auto theft protection sistem...

Страница 2: ...mmobilizer will follow its algorithms The driver s door was opened Upon entering the Guard mode AntiHiJack feature goes through a series of phases and in case if the Guard mode was not deactivated the...

Страница 3: ...e Wait for the confirming trill Maintenance mode Maintenance is an operation mode when all hijack protection and service functions of the Alarm are temporarily disabled The Alarm will notify of activa...

Страница 4: ...rolling on vehicles where CAN bus control is not available Please see Integrator files software product for information on vehicle specific connection features Pin No 6 Ground is connected to vehicle...

Страница 5: ...the steering wheel and steering wheel column joysticks buttons cruise control central unit control etc sequentially one after another Those buttons which after being pushed receive a response audible...

Страница 6: ...setting for PRIZRAK 520 1 4 1 1 maximum 2 high 3 low 4 minimum After the Immobilizer is installed adjusts the sensitivity 9 Hazard lights control algorithm 1 5 Set automatically but can be set manuall...

Страница 7: ...ange is within 5 to 10 km h 17 Front parking sensors control Generation of a constant level signal if the engine is on and the speed of the vehicle is less than 15 km h 18 Rear parking sensors control...

Страница 8: ...the brake pedal while the Immobilizer goes back to indication of the option number 7 Programming algorithm for function 10 Original buttons With the brake pedal pressed go to option 10 The Immobilizer...

Страница 9: ...y moment by turning off the ignition A trill will sound If no actions were taken within 60 seconds and brake pedal was released the Immobilizer will exit programming mode If the vehicle has travelled...

Страница 10: ...just the setting of option 3 by pressing the Programming button 2 times i e increase the option value by 2 increments 1 2 3 Immobilizer will acknowledge the selection by emitting a sequence of 3 audib...

Страница 11: ...ing PRIZRAK receives the information about the vehicle moving via CAN bus If the central unit was removed the relay will lock the engine using accelerometer once the vehicle starts moving yellow white...

Страница 12: ...l Manual PRIZRAK 510 520 v7 Use the picture to draw arrangement of alarm units This can help when trying to find specific units Keep this sketch out of the reach of third parties Immobilizer units arr...

Страница 13: ...arranty certificate 1 Connection diagram 1 Packing 1 Parameter Value Power supply voltage V 9 15 Maximum current consumption in standby mode mA 5 Maximum current consumption in standby mode mA 1200 fo...

Страница 14: ...14 TEC 61201 1 Technical Manual PRIZRAK 510 520 v7...

Страница 15: ...15 TEC 61201 1 Technical Manual PRIZRAK 510 520 v7...

Страница 16: ...Ltd The product is produced according to TU 4573 009 78025716 12 Certificate of conformityTS RU C RU OC13 B 01026 The product conforms to the requirements of the Technical reglament of Custom Union T...

Отзывы: