3
TEC-61201-1
Technical Manualе
PRIZRAK-510, 520 v7
Accelerator pedal lock (force to stop)
Feature will stop the vehicle if AntiHiJack was triggered minding
safe lock settings. Vehicle has to support «speed control». At the eng
of the warning phase, if speed of the vehicel didn’t increase within 5
seconds or brake pedal was pressed within 3 seconds, lock will activate
for 2 seconds, then it will be lifted for 5 seconds. This will be repeated
5 times. Every repetition lock lift will be reduced for 1 second. On fifth
repetition lock will be permanent.
PIN code entry sequence
•
Turn on the ignition or start the engine
•
Enter PIN code
•
Wait for the confirming trill.
Available PIN options
Buttons
,
,
,
,
are used here as an example. Request the list of avaliable buttons in your vehicle at your shop.
One-digit PIN:
Two-digit PIN:
~2 second pause
Single-button PIN entry
When entering the PIN code keep in mind the entering sequence.
One-digit PIN:
Two-digit PIN:
~2 second pause
PUK code
PUK code - 4-digit numbers under the scrach layer on the plastic
card that came with the Alarm. PUK-code will disable all security
features of the alarm. Use PUK-code only if you lost PIN-code.
After PUK code is entered, all security functions of the Alarm will be
deactivated regardless the selected authentication method.
PUK code can be found under the scratch layer on the plastic card.
•
The factory set PIN code is «2»; it is entered by using
the Programming button (please check the Integrator).
•
You can not assign a PIN-code «1» - one press of the
one button
PUK-code entry
PUK code is entered by the Programming button with a 2 second pause in between keystrokes.
Entering sequence:
•
Turn on the ignition or start the engine
•
Enter PUK code
•
Wait for the confirming trill.
Maintenance mode
Maintenance is an operation mode when all hijack protection and
service functions of the Alarm are temporarily disabled.
The Alarm will notify of activation of the Maintenance mode as
follows:
•
When disarming, LED will turn on
•
When the ignition is turned on, LED will go out
•
Warning trill after PIN-code entry
•
After the ignition is turned off, LED will light up and will be on
for a while.
To activate or deactivate the Maintenance mode follow these
steps:
1.
Turn off the ignition.
2.
Enter PIN code.
3.
Press the Programming button 6 times (you should start within
10 seconds after verification).
4.
Wait for confirmation of your actions:
•
If the Maintenance mode is on, the system will emit 1
audio signal, 1 light signal and a trill
•
If the Maintenance mode is off, the system will emit 2
audio signals, 2 light signals and a trill.
Automatic deactivation of the Maintenance mode
This function automatically disables the Maintenance mode after
a 10 km run. So even if you forget to disable this mode in the service
station, it will still be automatically disabled.
If Maintenance mode is activated by PUK code, it cannot be
automatically disabled.
If the vehicle does not support Speed control, automatic
deactivation of this feature will not be avaliable.
Other options
Immobilizer has several options to make your vehicle more
comfortable and secure.
Automatic window roll up
The system can be programmed so that the vehicle windows are
rolled up when engaging the lock.
Setting the electromechanical hood lock
You can install an optional (third-party) hood lock and program
the Immobilizer to lock the hood when locking the vehicle, and
open it only after enter PIN code.
Central lock control
If your vehicle does not have an integrated door lock activated
when driving (locking) or turning off the ignition (unlocking), this
option can be provided by the Immobilizer.