Version 12.11.2013 TEC-6050-2
CANTEC-F2 V5
P
a
g
e
15
CAN-bus
It is possible to enter the from table 6 chosen input function for each programmable input
into below table 5.
Programmable inputs configuration (MENU 2) – table 5
no.
Option
description
Setting range /
default
Notes (enter programmed/planned output
functions from table 6)
13 Input (-) pin 8
1-9/1
14 Input (-) pin 9
1-9/2
15 Input (+) pin 17
1-9/4
16 Input (-) pin 18
1-9/3
The setting range 1-9 in table 5, equals the available programmable input functions from
table 6.
Available programmable inputs functions – table 6
no.
Function
Function description
1
Central l
Comfort
Trigger input (impulse) for central locking. When input signal is >2
seconds, windows comfort closing is started. Windows’ closing stops
when the signal stops. CAN-bus or alternate.
2
Central
unlocking
Trigger input (impulse) for central unlocking. CAN-bus or alternate.
3
Trunk opening
Trigger input (impulse) for s opening the trunk lid via CAN-bus.
4
Hazard lights
activation
Trigger input (impulse) for hazard lights, one flash per impulse. On
some vehicles, uneven lamp blinking may be observed while the
impulses are fed evenly. CAN-bus or alternate.
5
Horn control
Trigger input (constant) activates the programmable output
function no. 7 – “panic on horn from external input”. Sound output
in intervals. Stopping the input feed stops this function.
6
Engine start
Engine starts via CAN-bus (only some Cadillac, Chevrolet, Hummer).
7
Central lock is
locked (status)
Trigger input (constant) to provide “locked” status in vehicles where
it is not available on CAN-bus (see vehicle-specific installation file).
8
Central lock is
unlocked
Trigger input (constant) to provide “unlocked” status in vehicles
where it is not available on CAN-bus (see vehicle-specific installation