46
11. AQ-VU synchronized recording
11-1. Connections
Main unit
AQ-VU
AQ-VU synchronization cable
o
Use an AQ-VU synchronization cable to connect the main unit’s
AQ-VU synchronized recording connector with the AQ-VU unit’s
SYNC IN connector.
o
Do not connect an AQ-VU synchronization cable when not using
synchronized operation.
o
Turn off the main unit and the AQ-VU unit before connecting or
disconnecting an AQ-VU synchronization cable.
11-2. Turning the units on
In order, turn the AQ-VU and the main unit on.
11-3. Settings
Set the AQ-VU for recording start and stop control, including the
clocks of both units.
o
Synchronized playback of the main unit and the AQ-VU is not
possible.
o
To synchronize the AQ-VU, set AQ-VU SYNCHRO to ON on the
AQ-VU SETTING screen.
o
The clocks of the main unit and the AQ-VU are not synchronized
automatically. Manually synchronize them on the ADJUST TIME
screen.
o
To synchronize operation with the main unit, connect the AQ-VU
only to the master unit. Do not connect it to a slave unit.
o
AQ-VU synchronization cannot be used with 204.8kHz sampling.
o
When not using the AQ-VU, set AQ-VU synchronization to OFF.
o
Always turn the AQ-VU off first when turning the units off.
o
If you turn the main unit off while the AQ-VU is still on, the AQ-VU
might start recording temporarily.
Make the following settings on the AQ-VU.
The unit might not work properly with settings other than the ones
below.
Recording Settings
VIDEO SIZE
FULL
PRE TRIG TIME
000sec
START MODE
EXT IN (CLK)
EXT IN LEVEL
LOW
Serial Communication
BAUD RATE
9600bps
o
See the operation manual included with the AQ-VU for the set-
tings of other functions.
Содержание WX-7000
Страница 1: ...WIDE BAND DATA RECORDER Owner s Manual Z WX 7000 D01190210J ...
Страница 84: ...84 19 Exterior drawings WX 7016 340 348 10 8 220 13 8 123 82 40 15 WX 7032 164 82 40 40 15 ...
Страница 85: ...85 WX 7064 246 82 40 40 40 40 15 WX 7096 360 370 396 19 Exterior drawings ...
Страница 86: ...86 19 Exterior drawings WX 7128 360 370 478 ...