409-35001
Rev C
74
of 92
The force calibration functions are located under the “Force” subpanel in the Calibration Panel.
To perform
force calibration, you must be logged in as TE Administrator. Prior to force calibration, the ACAL unit must be
connected to the USB-RT connection on the machine and the digital readout must be connected to ACAL load
cell and powered on. Position the ACAL unit under the anvil and center with centering tool part number
2216917-1 (see Figure 81).
Figure 81
Remove centering tool and then manually lower anvil to just above load cell.
The “Calibrate” button will open
the calibration certificate form window. The user must fill out all fields in this form prior to calibration (see Figure
82 thru Figure 85)
. Press the “Begin Calibration” button to start the force calibration motion sequence. When
calibration is complete, the calibration certificate will be opened, and the calibration graph will be populated
with the force position dat
e from calibration. To reopen the calibration certificate, press the “View Calibration
Certificate” button (
see Figure 77 and Figure 78).