409-35001
Rev C
12
of 92
Facilities Labeling
The machine part number, serial number, manufacture date, and electrical specification are given on the label
on the left side of the machine as shown in Figure 10.
Figure 10
Electric Supply Circuit
Electrical supply circuit must be 200-240VAC, 50/60Hz, single phase.
Pneumatic Supply
The pneumatic supply must be connected to the port provided in the machine base. Compressed air is
used to operate the pneumatic shuttle. Air consumption is minimal. Pressure for the pneumatic shuttle
should be set to the 80PSI.
CMP INSTALLATION
Uncrating / Lifting
The press, monitor, leveling feet, and other removed parts are shipped on one pallet and are shrink-
wrapped for protection. Remove the shrink-wrap and unpack the monitor, computer and other shipped
parts. Remove press from pallet by unbolting hold-down bolts on four legs and lifting up several inches
with a forklift. Use “2x4”
or equivalent wood blocking between underside of Top Horizontal Frame Plates
(see Figure 5) and forklift blades. Alternately, the machine may be lifted by lifting on the bottom frame
cross members (see Figure 5). In either case, keep forks spread as wide as possible for better stability.
Initial Assembly
1. Using the four supplied M8 x 12 long socket head screws (PN 6-1655316-7) per wheel, install the four
Caster Wheels (2256047-1) to bottom of Press Frame (2216143-7).
2. Install customer supplied 3-conductor power cord appropriate for the available voltage and current
capacity (200-240VAC, single phase, 10A) by routing it through right-angle cable gland (located on the
left side panel of the machine. On the inside of the machine, route cable up. Terminate ground wire to
PE ground stud on machine frame. Terminate phase wires to the enclosed main power disconnect
switch (see Figure 11).
Figure 11
3. Install customer-
supplied industrial airline to ‘Quick Disconnect’ input on lower back side of Press.
Verify that shop air input has a minimum of 552 kPa [80 psi] to CMP Air Regulator.