Trigger On Command
”–
(Only used
when “Use Serial Trigger” enabled)
This entry field
specifies the character sequence that will be sent to the COM port device to trigger or
query the device to start sending data.
“
Trigger Off Command
”–
(Only used when “Use Serial Trigger” enabled) This
entry field
specifies the character sequence that will be sent to the COM port device to stop the
device from sending data after a read is complete.
“
Data
Settings”–
This button opens the “When” COM
Data Settings window (see Figure 49)
where settings for reading and parsing data from the COM port device can be entered.
Selecting “OK” will store the settings entered, and selecting “Cancel” will discard changes to
the settings.
Figure 49
“
Maximum Data Length
”–
This entry field specifies the maximum number characters to
read from the device.
"Minimum Data Length"-
This entry field specifies the minimum number of characters
that must be read from the device for a successful scan.
“Parse substring starting at character number”–
This entry field specifies where in the
read data to start parsing characters. This is useful in some cases where the user may
only want to analyze a portion of the total data read from the device.
For example, if a “3”
is entered into this field and the data string “SN123456” is read from the device, the first
character parsed
would be “1”.
“
Number of characters to parse
”–
This entry field specifies how many characters from
the read data to parse, starting from character number specified in the “Parse substring
starting at character number” field. This is useful in some cases where the user may
only
want to analyze a portion of the total data read from the device. The sum of the number of
characters to parse and the start character number cannot exceed the minimum data