PAQ
B-232
・All specifications are subject to change without notice.
Example :
PAQ65D48-3325/PV; Represent positive logic, OVP/OCP Auto-restart
MODEL
ITEMS/UNITS
CH
PAQ65D48-2518
PAQ65D48-3318
PAQ65D48-3325
PAQ65D48-5033
1
2
1
2
1
2
1
2
Input
Voltage Range
V
36 - 76 VDC
Efficiency (Typ)
(*2)
%
86.0
87.0
90.0
Current (Typ)
(*2)
A
0.82
0.97
1.10
1.36
Output
Nominal Voltage
VDC
2.5
1.8
3.3
1.8
3.3
2.5
5
3.3
Minimum Current
A
0
Maximum Current
A
15
17
15
17
15
17
13
16
Maximum Current Combination
A
Io1+Io2 = 18A
Total Allowable Power
(*1)
W
Po1+Po2 = 37.5
Po1+Po2 = 49.5
Po1+Po2 = 65
Voltage Setting Accuracy
(*2)
%
±
2
Maximum Line Regulation
(*5) mV
±
6.6
±
10
±
6.6
Maximum Load Regulation
(*6) mV
±
16.5
±
25
±
16.5
Temperature Coefficient
0.02%/
℃
Maximum Ripple & Noise
(*4) mVp-p
75
100
75
100
75
100
Voltage Adjustable Range
(*3)
±
10%
Function
Over Current Protection
(Io1+Io2)
(*7)(*8)(*10)
105
~
160%
Current limiting with inverter shutdown (Option available : Refer to option table)
Over Voltage Protection
(*7)(*8)
120
~
140%
Inverter shutdown (Option available : Refer to option table)
Remote ON/OFF Control
(*8)
Negative logic (Option available : Refer to option table)
Parallel Operation
------------
Series Operation
------------
Environment
Operating Temperature
℃
-40 to +85
Storage Temperature
℃
-40 to +100
Operating Humidity
%
RH
5 ~ 95 (No dewdrop)
Storage Humidity
%
RH
5 ~ 95 (No dewdrop)
Vibration
At no operating, 10 - 55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (maximum 49.0 m/s²) X,Y,Z 1 hour each
Shock
196.1 m/s² (In package)
Cooling
(*8)(*9)
Convection cooling / forced air cooling with derating
Isolation
Withstand Voltage
Input - Output : 1.5kVDC for 1 min.
Isolation Resistance
More than 100Mohm at 25
℃
and 70 %RH, Input - Output : 500 VDC
Standards Safety Standards
Approved by UL60950-1, CSA 22.2 No.60950-1, EN60950
Mechanical
Weight (Typ)
g
40
Size (W x H x D)
mm
36.8 x 8.9 x 57.9 ( Refer to outline drawing)
PAQ65D48
PAQ65D48 Specifications
■ Basic Connection
■ Option Table
PAQ
65D
(*1) Use external fuse (fast blow type) for each unit.
(*2) Recommended input capacitor C1
-20
℃
to +85
℃
: 33µF electrolytic type capacitor.
-40
℃
to +85
℃
: 33µF ceramic capacitor or equivalent such
as 5 parallel 6.8µF ceramic type capacitor.
(*3) 22µF ceramic capacitor
Option :
ON/OFF Logic
OVP/OCP
Standard
Negative
Shut-down
/P
Positive
Shut-down
/V
Negative
Auto-restart
/PV
Positive
Auto-restart
(*1) Maximum allowable combination output power for both channel; also maximum output current for each channel and combination output current for
both channel should not exceeded.
(*2) At 48 VDC, ambient temperature = +25
℃
and air velocity = 2m/S; 5033: Io1 = Io2 = 7.5A; 3325, 3318, 2518: Io1 = Io2 = 8.5A.
(*3) Additional external components have to be connected; Both outputs are trim independantly; Refer to application notes.
(*4) Measured at Ta = 25
℃
, Vin = 48VDC and with external components connected;
refer to basical connection drawing. For all temperature range, please refer to the application notes.
(*5) 36 ~ 76 VDC with respect to nominal input line 48V; constant load; ambient temperature = +25
℃
.
(*6) No load ~ full load with respect to 50% of maximun load; other output: no load; constant input voltage; ambient temperature =+25
℃
.
(*7) CNT reset or manual reset. Auto-restart option available.
(*8) Refer to application notes.
(*9) Refer to output derating curve.
(*10) Percentage is with respect to maximum combination current which is 18A.
Option for “/C”
(/C, /CP, /CV, /CPV)
Each output voltage can be varied
simultaneously and by the same
proportion by one trimmer.
Measurement point for Vin
+Vin
Fuse 5A (*1)
C1
(*2)
+
Vin
36〜76VDC
CNT
-Vin
Vo2
Trim 2
Gnd
Trim 1
Vo1
L=50mm
C3 22uF (*3)
C2 22uF (*3)
+
-
-
+
Load
Load
Measurement point for Vo,
line & load regulation
Measurement point for output ripple & noise
Bandwidth for scope : 20MHz
Содержание PAQ100S48-1R2
Страница 36: ...B 260...