background image

PAQ

B-232

・All specifications are subject to change without notice.

Example :

PAQ65D48-3325/PV; Represent positive logic, OVP/OCP Auto-restart

MODEL

ITEMS/UNITS

CH

PAQ65D48-2518

PAQ65D48-3318

PAQ65D48-3325

PAQ65D48-5033

1

2

1

2

1

2

1

2

Input

Voltage Range 

V

36 - 76 VDC

Efficiency (Typ) 

(*2)

86.0

87.0

90.0

Current (Typ) 

(*2)

A

0.82

0.97

1.10

1.36

Output

Nominal Voltage 

VDC

2.5

1.8

3.3

1.8

3.3

2.5

5

3.3

Minimum Current 

A

0

Maximum Current 

A

15

17

15

17

15

17

13

16

Maximum Current Combination 

A

Io1+Io2 = 18A

Total Allowable Power 

(*1)

W

Po1+Po2 = 37.5

Po1+Po2 = 49.5

Po1+Po2 = 65

Voltage Setting Accuracy 

(*2)

±

 2

Maximum Line Regulation 

(*5) mV

±

6.6

±

10

±

6.6

Maximum Load Regulation 

(*6) mV

±

16.5

±

25

±

16.5

Temperature Coefficient 

0.02%/

Maximum Ripple & Noise 

(*4) mVp-p

75

100

75

100

75

100

Voltage Adjustable Range 

(*3)

±

10%

Function

Over Current Protection
 (Io1+Io2) 

(*7)(*8)(*10)

105 

 160% 

Current limiting with inverter shutdown (Option available : Refer to option table)

Over Voltage Protection 

(*7)(*8)

120 

 140% 

Inverter shutdown (Option available : Refer to option table)

Remote ON/OFF Control 

(*8)

Negative logic (Option available : Refer to option table)

Parallel Operation 

------------

Series Operation 

------------

Environment

Operating Temperature 

-40 to +85  

Storage Temperature 

-40 to +100  

Operating Humidity 

RH

5 ~ 95 (No dewdrop)

 

Storage Humidity 

RH

5 ~ 95 (No dewdrop)

 

Vibration 

At no operating, 10 - 55Hz  (sweep for 1 min.) 

Amplitude 0.825mm constant (maximum 49.0 m/s²)  X,Y,Z 1 hour each

Shock 

196.1 m/s² (In package)

Cooling 

(*8)(*9)

Convection cooling / forced air cooling with derating

Isolation

Withstand Voltage 

 Input - Output : 1.5kVDC for 1 min.

Isolation Resistance 

 More than 100Mohm at 25

 and 70 %RH, Input - Output : 500 VDC

Standards Safety Standards 

Approved by UL60950-1, CSA 22.2 No.60950-1, EN60950

Mechanical

Weight (Typ) 

g

40

Size (W x H x D) 

mm

36.8 x  8.9 x  57.9  ( Refer to outline drawing)

PAQ65D48

PAQ65D48 Specifications

■ Basic Connection

■ Option Table

PAQ

65D

(*1)  Use external fuse (fast blow type) for each unit.
(*2)  Recommended input capacitor C1

 

-20

 to +85

: 33µF electrolytic type capacitor.

 

-40

 to +85

: 33µF ceramic capacitor or equivalent such 

 

as 5 parallel 6.8µF ceramic type capacitor.

(*3) 22µF ceramic capacitor

Option :

ON/OFF Logic

OVP/OCP

Standard

Negative

Shut-down

/P

Positive

Shut-down

/V

Negative

Auto-restart

/PV

Positive

Auto-restart

  (*1) Maximum allowable combination output power for both channel; also maximum output current for each channel and combination output current for 

both channel  should not exceeded.

  (*2) At 48 VDC, ambient temperature = +25

 and air velocity = 2m/S; 5033: Io1 = Io2 = 7.5A; 3325, 3318, 2518: Io1 = Io2 = 8.5A.

  (*3) Additional external components have to be connected; Both outputs are trim independantly; Refer to application notes.
  (*4) Measured at Ta = 25

, Vin = 48VDC and with external components connected;

 

refer to basical connection drawing. For all temperature range, please refer to the application notes.

  (*5) 36 ~ 76 VDC with respect to nominal input line 48V; constant load; ambient temperature = +25

.

  (*6) No load ~ full load with respect to 50% of maximun load; other output: no load; constant input voltage; ambient temperature =+25

.

  (*7) CNT reset or manual reset. Auto-restart option available.
  (*8) Refer to application notes.
  (*9) Refer to output derating curve.
(*10) Percentage is with respect to maximum combination current which is 18A.

Option for “/C”

(/C, /CP, /CV, /CPV) 

Each output voltage can be varied 

simultaneously and by the same 

proportion by one trimmer. 

Measurement point for Vin

+Vin

Fuse 5A (*1)

C1

(*2)

+

Vin

36〜76VDC

CNT

-Vin

Vo2

Trim 2

Gnd

Trim 1

Vo1

L=50mm

C3 22uF (*3)

C2   22uF (*3)

+
-

-
+

Load

Load

Measurement point for Vo,

    line & load regulation

Measurement point for output ripple & noise

            Bandwidth for scope : 20MHz

Содержание PAQ100S48-1R2

Страница 1: ...eset V ON OFF control negative logic OVP automatic recovery B With baseplate PAQ100S48 only ON OFF control negative logic OVP manual reset Sample option combination PAQ100S48 5 BPV With baseplate ON O...

Страница 2: ...to option table Remote Sensing 6 Possible Remote ON OFF Control Possible Option availavle Refer to option table Parallel Operation 6 Series Operation 6 Possible Environment Operating Temperature 7 Ta...

Страница 3: ...20 40 60 80 100 1m s 2m s Air Velocity Natural convection cooling Ambient Temperature Load PAQ50S48 2R5 PAQ50S48 3R3 PAQ50S48 NOTES A Model name country of manufacture Lot No and safety marking TUV C...

Страница 4: ...Load Regulation 3 mV 10 Temperature Coefficient Less than 0 02 Maximum Ripple Noise 8 mVp p 100 Voltage Adjustable Range 8 20 10 15 Function Over Current Protection 4 105 140 Option availavle Refer t...

Страница 5: ...mm NOTES A Model name country of manufacture Lot No and safety marking TUV C UL US CE marking are shown here in accor dance with the speci cations B Output pin of V and V 2 1 5 C Signal and Input pin...

Страница 6: ...Coefficient Less than 0 02 Maximum Ripple Noise 8 mVp p 100 Voltage Adjustable Range 8 20 10 15 Function Over Current Protection 4 105 140 Option availavle Refer to option table Over Voltage Protecti...

Страница 7: ...ction on mountintg direction but there should be enough consideration for airflow so that heat does not accumulate around the power module vicinity Determine external components configuration and moun...

Страница 8: ...0 1 EN60950 Mechanical Weight Typ g 40 Size W x H x D mm 36 8 x 8 9 x 57 9 Refer to outline drawing PAQ65D48 PAQ65D48 Specifications Basic Connection Option Table PAQ65D 1 Use external fuse fast blow...

Страница 9: ...IEW BOTTOM VIEW NAME NOTE A MODEL NAME COUNTRY OF MANUFACTURE LOT NO AND SAFETY MARKING BSI C UL US CE MARKING ARE SHOWN HERE IN ACCORDANCE WITH THE SPECIFICATIONS B INPUT AND OUTPUT TERMINAL 8 1 0 C...

Страница 10: ...using with different measuring conditions from those of output derating by ambient tem perature use output derating to keep temperature of MOSFET Q15 below 125 Q15 temperature is decided by temperatu...

Страница 11: ...ng Synchronous Recti er Filter Bias Power Supply Control Circuit Shut Down Thermal Protection ON OFF Control Auto Restart OCP OVP LVP Voltage Sensing Sequence Time Chart Input Voltage Output Voltage 1...

Страница 12: ...oltage 1 1 Level H 2 V or Open 0 L 0 8 V or Short Vin 0 Vo1 Vo2 0 H L RESET More than 400ms OCP Set Point OVP Set Point ON OFF Control Input ON Control OFF Control ON Control ON Control ON OVP Trip OC...

Страница 13: ...al and signal terminal from the outside The injection of reverse voltage or over voltage exceeding nominal output voltage to output terminals might cause dam age to internal output capacitor Functiona...

Страница 14: ...take note that output spike noise voltage could vary according to PCB wiring design Maximum capacitance that can be connected between V and V is total 10 000 F C3 Input capacitor C3 is recommended to...

Страница 15: ...5 40 45 50 110 100 90 120 Input Voltage VDC 3 3V 5V Model 1 2V 1 8V 2 5V Models Output voltage Fig 2 1 Limit of Input Voltage Output Voltage Adjustment by external resistor or by variable resistor 1 I...

Страница 16: ...ment using coaxial cable Measure according to fig 3 2 Connect capacitors C1 ceramic capacitor 1 F C2 electrolytic capacitor 10 F at 50mm distance from the output terminals Measure at ceramic capacitor...

Страница 17: ...al to the load input terminal When remote sensing function is not used local sensing short S ter minal to V terminal and S terminal to V terminal Take note that voltage compensation range for line dro...

Страница 18: ...od and Thermal Condition Ambient Temperature vs Output Voltage Drift Temperature coefficient is defined as the rate of voltage change when ambient temperature is changed during op eration Withstand Vo...

Страница 19: ...Power Module Power Module Ta and air velocity measurement point Top view Fig 1 1 1 Output Derating by ambient temperature PAQ100S48 Vin 48VDC PAQ100S48 1R2 including V option 100 80 60 40 20 0 40 20 0...

Страница 20: ...cting thermocouple please take sufficient insulation from terminals Over Thermal Protection of power module is achieved by detecting the PCB temperature through thermal sensor When the module operates...

Страница 21: ...seconds 4 Recommended Cleaning Condition Recommended cleaning condition after soldering is as follows Cleaning solvent IPA isopropyl alcohol Cleaning Procedure Use brush and dry the solvent completely...

Страница 22: ...owing condition Output Voltage Nominal value Ambient Temperature 60 An example of thermal design using these condition is shown as follows 1 Example of Thermal design Calculate minimum necessary air v...

Страница 23: ...48 1R8 B Power dissipation vs Output Current Output voltage Nominal Ta 60 typical value 0 2 4 6 8 10 12 14 0 5 10 15 20 25 Output Current A Vin 36V Vin 48V Vin 76V Power Dissipation W Fig 1 6 PAQ100S4...

Страница 24: ...ection cooling 1m s 2m s Load Ambient Temperature Fig 1 9 PAQ100S48 1R2 B Output Derating at Ambient Temperature Vin 48V reference value 100 80 60 40 20 0 40 20 0 20 40 60 80 100 Air Velocity Natural...

Страница 25: ...Output terminal pin 1 5mm Hole diameter 2 0mm Land diameter 3 5mm M3 Mounting Tap FG Hole diameter 3 5mm Land diameter 5 5mm 4 Clearance from Customer Board Minimum clearance between PAQ100S48 B and a...

Страница 26: ...al output capacitor Functional Polymerized Capacitor The application circuits and their parameter are for reference only Be sure to verify effectiveness of application circuits and their parameters be...

Страница 27: ...F for each output 2 If using electrolytic capacitor use a low impedance type such as Nippon Chemicon LXV series or equivalent with excel lent temperature characteristics or parallel a few electrolytic...

Страница 28: ...Range Vo2 15 10 5 0 5 10 15 15 10 5 0 5 10 15 PAQ65D48 2518 Vo2 vs Vo1 Trim Range Vo2 10 1 2 1 5 10 10 2 7 0 8 10 5 10 15 Vo2 vs Vo1 nge 1 15 10 5 0 5 10 15 15 10 5 0 5 10 15 PAQ65D48 3325 Vo2 vs Vo1...

Страница 29: ...dj2 up k 459 232 156 118 95 2 80 1 69 3 61 1 54 8 49 8 Trim Down Vo 1 2 3 4 5 6 7 8 9 10 Radj2 down k 265 131 86 5 64 2 50 7 41 8 35 4 30 6 26 9 23 9 3 1 2 Standard PAQ65D48 3325 model i 3 3V Output T...

Страница 30: ...0 43 0 0 3 2 3 PAQ65D48 3318 C option model i Common Output Trim Up ii Common Output Trim Down Trim Up Vo 1 2 3 4 5 6 7 8 9 10 Radj up k 13 5 6 2 3 8 2 6 1 9 1 4 1 05 0 79 0 59 0 43 Trim Down Vo 1 2...

Страница 31: ...mally 9 Over Thermal Protection OTP This power module has built in OTP function This function operates and shuts down the output when temperature of the power module rises excessively The power module...

Страница 32: ...am below Vo1 TRM1 GND TRM2 Vo2 Vin Vin CNT WITHSTAND VOLTAGE TESTER Test condition 1 5kVDC 1minute 10mA Fig 17 1 Withstand Voltage Test for Input Output Insulation Resistance Use DC insulation tester...

Страница 33: ...o2 Output current A Ambient temperature 16 14 12 10 8 6 4 2 0 0 20 40 60 80 100 0 5m s 1m s 2m s 16 14 12 10 8 6 4 2 0 0 20 40 60 80 100 0 5m s 1m s 2m s 16 14 12 10 8 6 4 2 0 0 20 40 60 80 100 0 5m s...

Страница 34: ...wiring pattern b Mounting hole on PCB Below is the recommended diameter of hole and land of PCB Type Terminal Pin Hole Diameter Land Diameter PAQ65D48 1 0mm 1 3mm 2 8mm For position of the holes see o...

Страница 35: ...h For cases where output voltage adjustment is used is the resistor or volume setting connections cor rectly done 3 Output voltage is low Is specified input voltage applied For cases where output volt...

Страница 36: ...B 260...