Outline Drawing
Derating Curve
57.9±0.5
47.2±0.5
TOP VIEW
BOTTOM VIEW
50.8±0.25
36.8
±
0.5
12.7
±
0.5
26.16
±
0.25
4.1min
15.24
±
0.25
15.24
±
0.25
7.62
±
0.25
OPTION CODE
NOTE D
2-M3X0.5 THROUGH
NAME
NOTE A
2-Φ1.5
NOTE B
NAME
PLATE
6-Φ1.0 NOTE C
NOTE E
(unit : mm)
= NOTE =
A: Model name, country of manufacture, Lot No. and safety marking (TUV, C-UL-
US & CE marking) are shown here in accordance with the specifications.
B: Output pin of +V and -V : 2-
Φ
1.5
C: Signal and Input pin : 6-
Φ
1.0
D: OPTION CODE
100
80
60
40
20
0
−40
−20
0
20
40
60
80
100
2R5,3R3,5 model
1R2,1R8 model
Baseplate Temperature (℃)
Load (%)
Baseplate
temperature
measuring point
There is no restriction on mountintg direction but there should be enough
consideration for airflow so that heat does not accumulate around the power
module vicinity. Determine external components configuration and mounting
direction on PCB such that air could flow through power module at forced air
cooling or convection cooling.
By maintaining baseplate temperature below 100℃, operation is possible. Ac-
cording to the models, output derating is needed.
Measure baseplate temperature at center of baseplate.
For better improvement of power module reliability, more derating of baseplate
temperature when using is recommended.
PAQ
100S48-
*
/B
CODE
OVP/OCP
REMOTE ON/OFF CONTROL
/B
SHUT DOWN
(
ON/OFF CONT. RESET
OR MANUAL RESET
)
NEGATIVE
(
SHORT : ON
OPEN : OFF
)
/BV
AUTO RESTART
/BP
SHUT DOWN
(
ON/OFF CONT. RESET
OR MANUAL RESET
)
POSITIVE
(
SHORT : OFF
OPEN : ON
)
/BPV
AUTO RESTART
E: M3X0.5 tapped holes 2 for customer chassis mounting (FG).