PAQ
-S48
PAQ
B-244
・All specifications are subject to change without notice.
PAQ50S48-1R8 (including /V option)
100
80
60
40
20
0
−40
−20
0
20
40
60
80
100
Air Velocity
Natural convection cooling
1m/s, 2m/s
Ambient Temperature (℃)
Load (%)
Fig.1-8
PAQ50S48-2R5 (including /V option)
100
80
60
40
20
0
−40
−20
0
20
40
60
80
100
Air Velocity
Natural convection cooling
1m/s
2m/s
Ambient Temperature (℃)
Load (%)
Fig.1-9
PAQ50S48-3R3 (including /V option)
100
80
60
40
20
0
−40
−20
0
20
40
60
80
100
Air Velocity
Natural convection cooling
1m/s
2m/s
Ambient Temperature (℃)
Load (%)
Fig.1-10
PAQ50S48-5 (including /V option)
100
80
60
40
20
0
−40
−20
0
20
40
60
80
100
Air Velocity
Natural convection cooling
1m/s
2m/s
Ambient Temperature (℃)
Load (%)
Fig.1-11
(2)Output derating by PCB
When use with different measurement conditions from
output derating by ambient temperature, use output
derating by PCB temperature as in Fig.1-13 and
1-14. PCB temperature is decided by temperature
of thermal sensor in below Fig.1-12. As the ther-
mal sensor terminals are exposed, when connecting
thermocouple, please take sufficient insulation from
terminals. Over Thermal Protection of power module
is achieved by detecting the PCB temperature through
thermal sensor. When the module operates over the
output derating curve of PCB temperature, Over Ther-
mal Protection (OTP) functions and output shutdown.
Therefore, measurement of PCB temperature is rec-
ommended to ensure the module to operate within the
derating curve.
Top view
Thermal sensor
Output
Input
Fig.1-12 Thermal Sensor Position
Output Derating by PCB Temperature
100
80
60
40
20
0
−40
−20
0
20
40
60
80
100
PCB Temperature(℃)
Load (%)
Fig.1-13 Output Derating by PAQ100S48 PCB Temperature
100
80
60
40
20
0
−40
−20
0
20
40
60
80
100
PCB Temperature(℃)
Load (%)
Fig.1-14 Output Derating by PAQ50S48 PCB Temperature
2 Mounting Method
(1)Prohibition area of pattern wiring
Avoid wiring pattern on PCB in shaded area as
shown in Figure 2-1 as it may cause insulation prob-
lem.
Since the power module may influence by noise, care
must be taken when wire the signal line on the un-
shaded area.
+V
+S
TRM
-S
-V
+Vin
-Vin
CNT
36.8
6.2
23.3
3
17.2
8.5
(10.6)
10.2
15.6
10.2
6
5.3
(2.1)
4.4
8.1
5.8
16.4
5.1
4.4
32.7
57.9
9.7
5.5
9
(11.1)
Top View
Fig.2-1 Prohibition area of wiring pattern
Содержание PAQ100S48-1R2
Страница 36: ...B 260...