PAQ
65D
PAQ
B-250
・All specifications are subject to change without notice.
PAQ65D SERIES Instruction Manual
1. Terminal Descriptions
Be sure to take note of precautions and warnings indicated in
this manual when using this product. Improper usage may lead
to electric shock or fire. Be sure to read this instruction manual
thoroughly before using this product.
Caution
● There are high voltage and high temperature components
within this product. Refrain from disassembling this product
or touching its internal components as this may lead to elec-
tric shock or burned.
● When the unit is operating, keep your hands and face away
from the unit. You may get injured by accident.
● Confirm connections to input/output terminals and signal ter-
minals are correct as indicated in the instruction manual.
● Attach a fast blow type external fuse to each module to
ensure safety operation and compliance to each safety stan-
dard approval.
● This power module is designed for professional installation
within the end user equipment.
● Use isolated voltage by reinforced or double insulation as
input power source.
● Do not inject abnormal voltage to output terminal and signal
terminal from the outside.
● The injection of reverse voltage or over voltage exceed-
ing nominal output voltage to output terminals might cause
damage to internal output capacitor (Functional Polymerized
Capacitor).
● The application circuits and their parameter are for reference
only. Be sure to verify effectiveness of application circuits
and their parameters before finalizing circuit design.
● The information in this document is subject to change with-
out prior notice. For actual design-in, please refer to the lat-
est publications of data sheet, etc., for the most up-to date
specifications of the unit.
● No part of this document may be copied or reproduced in
any form, or by any mean without prior written consent of
Densei-Lambda.
Note:CE Marking
CE Marking, when applied to a product covered by instruction
manual, indicates compliance with the low voltage directive
which complies with EN60950
Before Using This Power Module
● Standard Model Input and Output Terminal Descriptions
● /C Option Model Input and Output Terminal Descriptions
TOP VIEW
Vo1
+Vin
CNT
−Vin
Vo2
TRM1
GND
TRM2
TOP VIEW
Vo1
+Vin
CNT
−Vin
Vo2
TRM
GND
[Input Terminal]
+Vin: Positive Input
CNT: ON/OFF Control
-Vin: Negative Input
[Output Terminal]
Vo1:
Channel 1 (CH1) Positive Output
TRM1: CH1 Output Voltage Trimming
GND: Output Ground (for CH1 & CH2)
TRM2: CH2 Output Voltage Trimming
Vo2: Channel 2 (CH2) Positive Output
[Input Terminal]
+Vin: Positive Input
CNT: ON/OFF Control
-Vin:
Negative Input
[Output Terminal]
Vo1:
Channel 1 (CH1) Positive Output
TRM: CH1 & CH2 Output Voltage Trimming
GND: Output Ground (for CH1 & CH2)
Vo2:
Channel 2 (CH2) Positive Output
● PAQ-S Instruction Manual
B-237Page
● PAQ100S48-*/B Instruction Manual
B-246Page
Содержание PAQ100S48-1R2
Страница 36: ...B 260...