2.3.2 GLOBAL PROGRAM OUTPUT VOLTAGE
The output voltage of all supplies can be programmed by sending the command:
GLOBal:VOLTage[:LEVel][:IMMediate][:AMPLitude]<SP>
<value>
where <value> is any valid voltage with or without a decimal place.
Alternate Format:
none
Example:
GLOBAL:VOLTAGE:AMPLITUDE 15.77
2.3.3 GLOBAL PROGRAM OUTPUT CURRENT
The output current
of all supplies are
programmed by sending the command:
GLOBALCURRent[:LEVel][:IMMediate][:AMPLitude]<SP><value>
where < value > is any valid current with or without a decimal place.
Alternate Formats:
none
Examples:
GLOBal:CURRENT:AMPLITUDE 15.77
2.3.4 GLOBAL EANBLE THE SUPPLY OUTPUT COMMAND
All power supply outputs can be turned on by sending this command:
GLOBal:OUTPut:STATe<SP>1
The output will immediately jump to the last programmed voltage and current.
Example:
GLOBAL:OUTPUT:STATE 1
Notes:
1 can be replaced with ON
2.3.5 GLOBAL DISABLE THE SUPPLY OUTPUT COMMAND
All power supply outputs can be shut off by sending this command:
GLOBal:OUTPut:STATe<SP>0
This command is equivalent to programming the output to zero volts.
Example:
GLOBAL:OUTPUT:STATE 0
Notes:
0 can be replaced with OFF
2.3.6 GLOBAL RESET COMMAND
Resets all Power Supplies. Voltage and current are set to 0. Supply output is set to OFF.
Supply enters Remote Mode Operation.
Syntax:
GLOBal:*RST
Example:
GLOBal:*RST