2.2.11 GO TO REMOTE MODE COMMAND
Places the supply under control of the IEEE Interface.
Syntax:
SYSTem:SET<SP><1>
Example:
SYSTEM:SET 1
Notes:
1 can be replaced with REM
2.2.12 GO TO REMOTE WITH LOCAL LOCK OUT COMMAND
Places the supply under control of the IEEE Interface and disables the Front Panel Go To Local
Button.
Syntax:
SYSTem:SET<SP><2>
Example:
SYSTEM:SET 2
Notes:
2 can be replaced with LLO
2.2.13 READ PROGRAMMING MODE COMMAND
Reads the mode of the Power Supply. Place a 0 in the output queue if the supply is in Local
Mode, a 1 if the supply is in Remote Mode and a 2 if the supply is in Remote Mode with Local
Lock Out.
Syntax:
SYSTem:SET?
Example:
SYSTEM:SET?
Returns:
“LOC”
“REM”
”LLO”
2.3 GLOBAL OUTPUT COMMANDS
2.3.1 USAGE
%
Global Commands are not SCPI compliant
%
Supplies acting upon Global Commands need not be a currently addressed supply
%
All supplies attached to the Interface must be capable of accepting Global Commands
%
No messages, OPC or Not Busy will be returned to the HOST PC after a Global Command has been is-
sued. The Busy Bit of the Status Byte, see Figure 1 and Figure 2, will be set to 0 after this command is
issued.
%
It will be the responsibility of the User Software to add a 200 Ms delay after each Global Command is
issued and before any other command can be issued.