CLRBB
Description
This command resets the XBL telemetry data.
Command Syntax
CLRBB
Example
CLRBB
This will reset the units telemetry data (returned by the commands
MAXVOL?, MAXCUR?, MAXPWR?) to zero.
Query Syntax
CLRBB
Returned Parameters
NONE
CON?
Condition register
Description
This query returns the contents of the Condition register and clears
its contents. The response is either numeric or a text description
depending on the TEXT ON/OFF and STATXT ON/OFF settings.
Each bit in this register provides information about the load’s
condition. A bit being set indicates that the condition is present or
has occurred. Normally the bit will clear when the condition clears
unless its respective bit in the Latch (LAT) register is set.
Furthermore if its respective bit in the Shutdown (SDN) register is
set the load will shutdown.
The returned value will be between 0 and 255 and is the sum of the
individual bit weights. A *CLS command will clear this register as
well. The individual bits are defined below.
B
it
Weigh
t
Description
Text On Response
Message
7
128
Under Voltage
UNDER VOLTAGE
6
64
Over Voltage
VOLTAGE LIMIT
5
32
Over Temperature
TEMPERATURE LIMIT
4
16
Minor Fault
MINOR FAULT
3
8
Over Current
CURRENT LIMIT
2
4
Over Power
POWER LIMIT
1
2
Saturation
LOAD SATURATED
0
1
Major Fault
MAJOR FAULT
The text response will return a string containing the Text On
Response Message as listed above for each bit that is set. These will
be separated by commas. If no bits are set, “CLEAR” will be
returned.
Command Syntax
NONE
Page 58 Of 162
Содержание XBL 400
Страница 61: ...CR See query form of CRH and CRL that immediately follows XBL Series 404078 Rev P2 odt Page 61 Of 162 ...
Страница 94: ...MDL Alternate form of ID query Page 94 Of 162 ...
Страница 108: ...RNGS Alternate form of RNG Query Page 108 Of 162 ...
Страница 120: ...SN Alternate form of SERNO query Page 120 Of 162 ...
Страница 160: ...Page 160 Of 162 ...