E– and E+ Power Input Connections
Referring to, E– and E+ are the power inputs for connecting the power source to be monitored
or tested.
The E– and E+ power inputs are the large threaded bolts (studs) on the rear of
the unit.
Use the shortest cables that are large enough in cross-sectional area to handle the
power source's current output. Twist and bundle the E+, E– cable(s) as a means of reducing self-
inductance. Also, use heavy-duty lugs and nuts to secure the E+, E– cables to the studs. Connect
only the power source load cables to these studs; all other connections must be made via the
terminal strip located below the studs.
CAUTION:
Only the power source-to-load connections are to be made to these studs.
The Master /Slave connectors:
These two connectors are CAM bus RJ 12, 6X6 ,Type located on the left rear of the unit
The “IEEE-488” Connector
This is used for computer control and uses a standard IEEE-488 cable (refer to).
Ethernet Communications Connector:
Located on all XBL models. It is an RJ45 connector
AC Input
This connection provides the Dynaload with its operating power and its safety ground. Power
requirements are user selectable as follows: Note on 800W units only 120 VAC and 240 VAC
are available.
100V, 1.8A / 120V, 1.5A
200V, 0.9A / 240V, 0.8A
47Hz – 63Hz
Input Voltage Selector
WARNING:
Ensure that the power cord is removed before making changes to the
voltage selector tab.
The AC input module on the rear of the Dynaload will have one of two possible selectors. Only
the labeling on the selector is different, the applicable ranges are identical. The selector will be
labeled as follows:
[100,120,200,240]
...or...
[115,125,230,250] ..or [100,120,220,240]
set the voltage selector position for your input voltage. The selected voltage should be
positioned adjacent to the molded arrow on the top of the input module.
XBL Series 404078 Rev P2.odt Page 13 Of 162
Содержание XBL 400
Страница 61: ...CR See query form of CRH and CRL that immediately follows XBL Series 404078 Rev P2 odt Page 61 Of 162 ...
Страница 94: ...MDL Alternate form of ID query Page 94 Of 162 ...
Страница 108: ...RNGS Alternate form of RNG Query Page 108 Of 162 ...
Страница 120: ...SN Alternate form of SERNO query Page 120 Of 162 ...
Страница 160: ...Page 160 Of 162 ...