SF
Slew Fast
Set for fast slew range
Description
This command is used to set the slew rate limiter to the fast range.
In the fast range, full-scale rise and fall times can be programmed
between 10
µ
s and 4000
µ
s using the SR, S1 or S2 commands.
NOTE:
Maximum slew rate is highly dependent on factors including
power source, source to load wiring, and operating mode.
Command Syntax
SF
Example
SF
Sets the slew rate limiter to the fast range.
Query Syntax
NONE
Returned Parameters
NONE
XBL Series 404078 Rev P2.odt Page 117 Of 162
Содержание XBL 400
Страница 61: ...CR See query form of CRH and CRL that immediately follows XBL Series 404078 Rev P2 odt Page 61 Of 162 ...
Страница 94: ...MDL Alternate form of ID query Page 94 Of 162 ...
Страница 108: ...RNGS Alternate form of RNG Query Page 108 Of 162 ...
Страница 120: ...SN Alternate form of SERNO query Page 120 Of 162 ...
Страница 160: ...Page 160 Of 162 ...