I2
Constant Current Pulsing Peak Level
Description
This command is used to set the peak level relative to the base level
when pulse loading in the Constant Current mode.
Command Syntax
I2 <NR2>
Example
I2 25.0
This will set the peak level to 25 Amps above the base level.
Therefore if the base level setting is 10.5A, the peaks will be 35.5
Amps.
Query Syntax
I2?
Returned Parameters
TEXT ON: <NR2> amps
TEXT OFF: <NR2>