Indication and operating elements 

 

Term 

Function 

Reset

 push button 

  for reset, restart the software 

  to reload factory settings  

button 

Reload factory 

setting WE

 

  to reload factory settings  

Status indication  
TCS:BUS  
(red LED) 

 

OFF

: stand-by 

 

ON

: during a voice connection between TCS:BUS and PBS / PSTN 

 

both LEDs ON

: when reloading the factory setting

 

 

 

blinks slowly

: busy (voice connection or alarming, announcement) 

 

blinks fast

: a-wire is not connected or supplied 

 

flashes OFF

: device is activated for programming with configuration software 

configo™ 

 

flashes ON

: door call, internal call or sensor signal received 

 

flashes ON, once, long break

: a-, P-wire are exchanged or short-circuited 

 

flashes ON, twice, long break

: error duplication of the block number and 

different device versions 

 

flashes ON, three times, long break

: error duplication of the block number 

in case of identic devices 

Status indication 
PBX / PSTN connec-
tion (yellow LED) 

 

OFF

: error P-wire is not connected or not supplied 

 

ON, briefly

: as long as a call signal comes in at the TK-Interface 

 

ON

: after a door call, during connection establishment and voice connection 

 

both LEDs ON

: when reloading to factory settings

 

 

 

blinks slowly

: programming mode active 

 

blinks fast

: once, connection to the PBX / PSTN cannot be realised, occu-

pied 

 

flashes OFF

: after a door call with deviated connection establishment, until 

the end of the delay time 

 

flashes ON

: connection to the sensor without speaking 

 

flashes ON, once, long break

: variant with 16 dialing registers 

 

flashes ON, twice, long break

: variant with 4 dialing registers 

 

flashes ON, three times, long break

: variant with 32 or 64 dialing registers 

 
 
 
 

Intended use 

 

  The FBO1100 is an interface for the connection from the TCS:BUS to a telephone net in 

order to establish a voice connection between a TCS:BUS client (front-door or indoor 
stations) and a client within the telephone net. 

  The connection is realised via an analogue port. 

  Up to 64 FBO1100 can be connected to a TCS:BUS. 

 
 
 
 
 
 
 
 

Содержание FBO1100-0400

Страница 1: ...ControlSysteme AG TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail info tcsag de PI_FBO1100_uk 1A Product information Interface for TK systems FBO110...

Страница 2: ...2 04 2013 TCS T rControlSysteme AG TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1100_uk 1A...

Страница 3: ...0 Error detection and indication 11 Configuration 12 Factory settings 12 Configuration options 12 Programming the FBO1100 13 Brief overview of all commands 13 Causal link between serial numbers and di...

Страница 4: ...V alternating voltage the safety regu lations according to DIN VDE 0100 must be observed When installing TCS BUS systems the general safety regulations for telecommunication systems according to VDE 0...

Страница 5: ...technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1100_uk 1A Device overview connection TCS BUS connection sensor connection actuator connection PBX PSTN Reset push button push but...

Страница 6: ...long break error duplication of the block number in case of identic devices Status indication PBX PSTN connec tion yellow LED OFF error P wire is not connected or not supplied ON briefly as long as a...

Страница 7: ...ne telephone specific triggering of up to 10 actuators per dialing register with a standard cell phone telephone day night mode call diversion from the indoor station to the TK Interface actuator pote...

Страница 8: ...rControlSysteme AG TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1100_uk 1A Wiring diagram minimum installation PBX PSTN an...

Страница 9: ...Legends Acknowledgement and signal tones after a call aQ programming mode ON entry is stored aQ call at the TK Interface aQ entering the Pin is required aQ entry invalid aQ end of connection Keystroke...

Страница 10: ...ng break This corresponds with the TK Interface 16 dialing register delivery state blink mode also see Indication and operating elements page 6 First check the connection of the FBO1100 to the telepho...

Страница 11: ...ntly see table below The optical error indication at the TK Interface stays active until the error is corrected error causes red LED yellow LED error tone description solution TCS BUS is busy blinks s...

Страница 12: ...of the dialing start x x 27 enter the successor of the dialing register ID in case of call diver sion x x 28 add the night dialing register ID to the storage space in case of day night mode x x 29 ac...

Страница 13: ...eload factory setting 1 activate always automatically 0 0 PSTN 1 PBX 2 Hotline 2 0 X Setting the exchange type 0 Exchange code 2 1 X oder X X Enter the exchange code special case 01 FLASH 02 MFV 03 MF...

Страница 14: ...short 10 s long 45 s 1 0 16bit short 1 32 bit long 4 1 X Setting the door release command 0 0 short 1 9 30s 30 270 s 4 2 X Setting the delay time 0 0 commands 1directly to AS 2 4 3 X Setting the reac...

Страница 15: ...ted to 10 block numbers per table You can receive more detailed tables on request The white fields in the table state the serial number Variant with 4 dialing registers Block number Dialing register 1...

Страница 16: ...hanges FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1100_uk 1A Variant with 64 dialing registers Block number Dialing register 10 min Dialing register 73 max 24 960 1023 23 896 959 22 832 895 2...

Страница 17: ...delivery state of all FBO1100 block number 72 ATTENTION If the block number is changed after the assignment of the bell buttons the FBO1100 does not react when pressing these bell buttons The bell but...

Страница 18: ...13 TCS T rControlSysteme AG TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1100_uk 1A via TCSK 01 directly at the FBO1100 ma...

Страница 19: ...TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1100_uk 1A Settings Communication time Number of ring tones signals entry 11...

Страница 20: ...TCS T rControlSysteme AG TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1100_uk 1A Actuator output switch time Call time Cha...

Страница 21: ...programming mode is lost This number can be reset only to 0000 by reloading the factory setting Press the button Load factory settings and keep it pressed At the same time shortly press the Reset butt...

Страница 22: ...ations of conformity are available under www tcsag de downloads trade information Information on disposal The adjoining symbol shows that the device has to be disposed separateley from domestic waste...

Страница 23: ...04 2013 23 TCS T rControlSysteme AG TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1100_uk 1A...

Страница 24: ...to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1100_uk 1A Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwis...

Отзывы: