12
04/2013
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
Mail: [email protected]
PI_FBO1100_uk 1A
Configuration
Factory settings
Factory settings see
FBO1100 short overview of all commands
.
Configuration options
co
mm
and
function
manually
configo
TM
as of version
1.6.0.6
10
enter a PIN
x
x
11
determine the dialing register number for the sensor
x
x
12
enter or delete a call number in the dialing register
x
x
13
check the content of the dialing register XX
x
–
14
assignment of a TK-Interface dialing register to a bell button
x
– *
15
set the minimum duration of a conversation
x
x
16
determine the number of the calls until the TK-Interface accepts
the call
x
x
17
set the activation time of the output port for
button
x
x
18
set the block number for the TK-Interface
x
x
19
service function listen-in
x
–
20
set the exchange
type
x
x
21
enter the exchange code
x
x
22
train an internal client to the
buttons 4 / 5 / 6,
delete the
buttons 4 / 5 / 6
x
x
23
control remote maintenance
x
–
24
define the function of the sensor
x
x
25
define the type of the connection start.
Not in case of a call diversion!
x
x
26
set the delay of the dialing start
x
x
27
enter the successor of the dialing register ID in case of call diver-
sion
x
x
28
add the night dialing register ID to the storage space in case of day
/ night mode
x
x
29
activation of the actuator port when a call comes in via
dialing register
x
x
30
duration of the call for this dialing register
x
x
31
control of the connection establishment
x
x
32
control of the acknowledgement tone during a call from a front-
door station
x
x
33
enter the AS-address to the sensor in case of a voice connection
x
x
34
starts the transmission of the internal parameter block of the TK-
Interface
x
x
35
starts the read-out of the parameter block to the dialing register
x
x
36
enter the project number with 4 digits
x
–
37
control of the error tone output
x
x
38
set the function of an internal call to the TK-Interface
x
x
39
activate the function input PIN
x
x
40
set the timeout after the dialing
x
x
41
set the door release commands
x
x
42
set the delay time
x
x
43
set the reaction on a call at the TK-Interface
x
x
44
blank dial tones / do not modify
x
x
45
acoustic note
”call at a TK-Interface” when incoming call on / off
x
x
46
number of the dialing register / set the type of the TK-Interface
x
x
47
activate / deactivate number mode
x
x
48
activate the training of the serial number to the number mode
x
x
* in connection with configuration of the front-door station