04/2013
7
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
Mail: [email protected]
PI_FBO1100_uk 1A
Short description
connection via a standard PBX / PSTN analogue interface
sensor to trigger a connection establishment / separate dialing register
sensor requires the connection of a potential-free switch
dialing register with 4, 16, 32, or 64 call numbers with max. 16 digits, can be pro-
grammed/adjusted, delivery state: 16 dialing register
telephone buttons of standard telephones and cell phones switch door release, lights
and create control functions via multi-frequency dialing
specific connection to 56 front-door stations with a standard (cell phone) telephone
specific internal call from up to 3 indoor stations with a standard (cell phone) telephone
specific triggering of up to 10 actuators per dialing register with a standard (cell phone)
telephone
day / night mode
call diversion (from the indoor station to the TK-Interface)
actuator, potential-free relay contact (two-way contact: 24 V DC / 1 A)
switch time of the relay ex works: 10 seconds / adjustable via MFV (multi-frequency di-
aling)
up to 64 FBO1100 can be connected to one TCS:BUS
status indication for operation modes and transmission state
optical error indication
configuration via DTMF (multi-frequency dialing) or configuration software con
figo™
(as of version 1.6.0.6)
busy tone detection to terminate the conversation automatically, only hang-up the hand-
set
energy-saving when in stand-by mode (240 mW)
Connect the lines
The FBO1100 is connected to the PBX / PSTN just like an analogue telephone.
The FBO1100 needs a TCS:BUS, that at least consists of power supply and control unit
and a front-door station. Alternatively, also indoor stations can use the FBO1100 as in-
terface.
Connection diagram