For the user operation safety, cut off the power before installation.
We recommend connecting a DC fuse corresponding to the conductor between battery and Energier pro Inverter Charger
Combination,which will offer protection to the battery cable. Please refer to following chart of our recommendations.
Ensure that the Energier pro Inverter Charger Combination has the correct DC voltage with your existing battery system.
Install Energier pro Inverter Charger Combination as close to the batteries as possible reducing the voltage drop on cable
for the better performance of the equipment.
On the AC output side, we recommend connecting the output from Energier pro Inverter Charger Combination to a suitable
Residual Current Circuit Breaker and Circuit Breaker.
The neutral of this equipment is not connected to the earth. If requested, additional devices need to be installed internally.
Please contact your installer.
Do not connect the output of this equipment to your AC system at the same time as any other AC source
such as the 230V external mains or a generator.
6. Installation and Connection
6.1 General advice
12 VDC model
Systemcapacity
24 VDC model
48 VDC model
CF20xx
CF30xx
CF40xx
500 A
CF50xx
CF60xx
CF80xx
/
/
175 A
325 A
/
/
400 A
/
/
200 A
250 A
300 A
CF12xx
CF08xx
CF16xx
250 A
300 A
150 A
200 A
100 A
150 A
250 A
75 A
125 A
125 A
/
/
80 A
/
Содержание Energier Pro CF2060L
Страница 1: ...User Manual Energier Pro series Inverter Charger Combination TBB Power CO ltd www tbbpower com A3 4...
Страница 2: ...Energier pro User Manual...
Страница 23: ...Energier pro User Manual 16 3 1 2 RCF remote 3 1 3 Vision Lite 3 1 4 AGS 3 1 5 TAI...
Страница 25: ...Energier pro User Manual 18 3 CF4080M CF50100M CF5050S CF6060S CF8080S 3 2 2 RCF remote 3 2 3 Vision Lite...
Страница 26: ...Energier pro User Manual 19 3 2 4 AGS 3 2 5 TAI...
Страница 59: ...Energier pro User Manual...