Energier pro User Manual
7
The Energier pro Inverter Charger Combination has two operating modes built in. With threshold setting under standard mode, Energier pro
Inverter Charger Combination will charge battery upon available AC and provide power to any loads connected. Upon power failure, Energier
pro Inverter Charger Combination will automatically transfer to inverter taking energy stored in the battery.AC priority
Under SOLAR mode, you can use Energier pro Inverter Charger Combination to compose a solar hybrid system, of which solar energy will be
used as priority and will bring grid/D.G. in and meantime charge battery upon battery runs to protection level. DC Priority.
2.10 Solar mode
In Power Save mode, the no load power consumption will be reduced by approx 70%. Energier pro Inverter Charger Combination will switch
off in case of load is less than preset level and will resume after the power reach the preset level.
Energier pro Inverter Charger Combination offers the approach to fully adjust this entry level. Please refer to chapter 7.11 for detail instruction.
You can also achieve this programming through optional Vision Lite or Rapconfig .
2.12 Power Save Mode (PS mode)
In systems with a small generator, if the output voltage is too unstable and distorted to be used. The Energier pro Inverter Charger Combination
won’t deliver charge and will remain in inverter mode. In this application, you can set Energier pro Inverter Charger Combination to GEN mode,
after which Energier pro Inverter Charger Combination will reduce its requirement for AC input (voltage, frequency and waveform). As a
consequence, the transfer time will be prolonged to about 2s. The load may have problem of loss of power in case of transfer.
In some applications such as sudden overload in short period such as starting Vacuum cleaner on generator, the output voltage of generator
will be decreased dramatically. The switch at this circumstance is not desired. You could also set GEN mode.
Through Vision Lite or Rapconfig, the voltagerange can be programmable.
2.11 Gen mode
Содержание Energier Pro CF2060L
Страница 1: ...User Manual Energier Pro series Inverter Charger Combination TBB Power CO ltd www tbbpower com A3 4...
Страница 2: ...Energier pro User Manual...
Страница 23: ...Energier pro User Manual 16 3 1 2 RCF remote 3 1 3 Vision Lite 3 1 4 AGS 3 1 5 TAI...
Страница 25: ...Energier pro User Manual 18 3 CF4080M CF50100M CF5050S CF6060S CF8080S 3 2 2 RCF remote 3 2 3 Vision Lite...
Страница 26: ...Energier pro User Manual 19 3 2 4 AGS 3 2 5 TAI...
Страница 59: ...Energier pro User Manual...